Basic-type digital temperature controller
Hide thumbs Also See for E5CN-U:

Advertisement

USB-Serial Conversion Cable
Applicable OS
Windows 2000, XP, or Vista
Applicable software
CX-Thermo version 4 or higher
E5AN/E5EN/E5CN/E5CN-U/E5AN-H/
Applicable models
E5EN-H/E5CN-H/E5GN
USB interface standard Conforms to USB Specification 1.1.
DTE speed
38400 bps
Computer: USB (type A plug)
Connector
Temperature Controller: Setup Tool port
specifications
(on bottom of Controller)
Bus power (Supplied from USB host
Power supply
controller.)
Power supply voltage
5 VDC
Current consumption
70 mA
Ambient operating
0 to 55°C (with no condensation or icing)
temperature
Ambient operating
10% to 80%
humidity
−20 to 60°C (with no condensation or
Storage temperature
icing)
Storage humidity
10% to 80%
Altitude
2,000 m max.
Weight
Approx. 100 g
Note: A driver must be installed in the personal computer. Refer to
installation information in the operation manual for the
Conversion Cable.
Communications Specifications
Transmission line
RS-485: Multipoint
connection method
Communications
RS-485 (two-wire, half duplex)
Synchronization
Start-stop synchronization
method
Protocol
CompoWay/F, SYSWAY, or Modbus
1200, 2400, 4800, 9600, 19200, 38400, or
Baud rate
57600 bps
Transmission code ASCII
Data bit length *
7 or 8 bits
Stop bit length *
1 or 2 bits
Vertical parity (none, even, odd)
Frame check sequence (FCS) with SYSWAY
Error detection
Block check character (BCC) with
CompoWay/F or CRC-16 Modbus
Flow control
None
Interface
RS-485
Retry function
None
Communications
217 bytes
buffer
Communications
0 to 99 ms
response wait time
Default: 20 ms
* The baud rate, data bit length, stop bit length, and vertical parity can
be individually set using the Communications Setting Level.
Current Transformer (Order Separately)
Ratings
Dielectric strength
1,000 VAC for 1 min
Vibration resistance 50 Hz, 98 m/s
E54-CT1: Approx. 11.5 g,
Weight
E54-CT3: Approx. 50 g
Accessories
Armatures (2)
(E54-CT3 only)
Plugs (2)
Heater Burnout Alarms, SSR Failure
Alarms, and Heater Overcurrent Alarms
Models with detection for single-phase
CT input
heaters: One input
(for heater current
Models with detection for single-phase
detection)
or three-phase heaters: Two inputs
Maximum heater current 50 A AC
Input current indication
±5% FS ±1 digit max.
accuracy
Heater burnout alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range *1
Minimum detection ON time: 100 ms
SSR failure alarm
0.1 to 49.9 A (in units of 0.1 A)
setting range *2
Minimum detection OFF time: 100 ms
Heater overcurrent
0.1 to 49.9 A (in units of 0.1 A)
alarm setting range *3
Minimum detection ON time: 100 ms
*1. For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output assigned to the
alarm 1 function will turn ON if the heater current is lower than the
set value (i.e., heater burnout detection current value).
*2. For SSR failure alarms, the heater current will be measured when
the control output is OFF, and the output assigned to the alarm 1
function will turn ON if the heater current is higher than the set
value (i.e., SSR failure detection current value).
*3. For heater overcurrent alarms, the heater current will be
measured when the control output is ON, and the output assigned
to the alarm 1 function will turn ON if the heater current is higher
than the set value (i.e., heater overcurrent detection current
value).
Electrical Life Expectancy Curve for
Relays (Reference Values)
500
300
100
50
30
10
5
E5CN
250 VAC, 30 VDC
3
(resistive load)
cosφ = 1
1
0
1
2
3
4
Switching current (A)
Note: Do not connect a DC load to a Controller with a Long-life Relay
Output.
E5CN/E5CN-U
2
5
6
10