Honeywell SS500 Series Installation Instructions

Temperature compensated hall effect sensors

Advertisement

Quick Links

Installation Instructions for the
SS500 Series Temperature Compensated
Hall Effect Sensors
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE
This component is sensitive to electrostatic discharge
(ESD). Take normal ESD precautions in handling this
product to prevent ESD-induced damage and/or
degradation.
Failure to comply with these instructions will
result in product damage.
CAUTION
WAVE SOLDER DAMAGE
DO NOT wave solder this product. Wave soldering
may negatively affect the sensor performance and
reliability. Subjecting the sensor to wave soldering
will void Honeywell's warranty.
Failure to comply with these instructions will
result in product damage.
OPERATING CHARACTERISTICS (over Operating Voltage and Temperature, unless otherwise noted)
Supply Voltage
Current Consumption
Output Voltage (operated)
Output Current (operated)
Output Leakage Current (released)
Output Switching Time
Rise, 10 to 90%
Fall, 90 to 10%
Operating Temperature Range
Note: To prevent damage to the leads, SS500 Series surface mounted sensors are
supplied only on tape and reel.
Sensing and Control
ABSOLUTE MAXIMUM RATINGS*
Supply Voltage
Voltage externally
applied to output
Output ON Current
Operating Temperature
Storage Temperature
Magnetic Flux
* Absolute maximum ratings are the extreme limits that the
device will withstand without damage to the device.
However, the electrical and mechanical characteristics are
not guaranteed as the maximum limits (above
recommended operating conditions) are approached, nor
will the device necessarily operate at absolute maximum
ratings.
SOLDERING INSTRUCTIONS
Honeywell recommends an infrared reflow process
with peak temperatures not to exceed 245°C (473°F)
for 10 seconds maximum.
BLOCK DIAGRAM
Min.
Typ.
Max.
3.8
30
10
0.15
0.40
20 mA
10 µA
.05 µs
1.5 µs
.15 µs
1.5 µs
-40°C to +125°C (-40°F to 302°F)
-1 to +30 VDC
+30 VDC max. (OFF only)
-0.5 VDC min. (OFF or ON)
See Table A.
-50 to +160°C
(-67 to +320°F)
-65 to +160°C
(-85 to +320°F)
No limit. Circuit cannot be
damaged by magnetic
overdrive.
TRIGGER
HALL
CIRCUIT
SENSOR
AND
AMPLIFIER
Remarks
VDC
mA
Sinking 20 mA max.
V
= 12 V,
CC
= 1.6 K Ω,
R
L
C
= 20 pF
L
ISSUE 5
PK 80079
Vs (+)
OUTPUT
(0) N.H.
GROUND (-)
TABLE A
Output Current
Absolute Limits
Supply
Output
Voltage
Current
Max. mA
-1 to 24
50
24 to 25
37
25 to 26
33
26 to 27
28
28 to 29
19
29 to 30
15

Advertisement

loading

Summary of Contents for Honeywell SS500 Series

  • Page 1 Fall, 90 to 10% = 20 pF 29 to 30 Operating Temperature Range -40°C to +125°C (-40°F to 302°F) Note: To prevent damage to the leads, SS500 Series surface mounted sensors are supplied only on tape and reel. Sensing and Control...
  • Page 2 Bipolar Hall effect sensors may have an initial output in either the On or Off state if powered up with an applied magnetic field in the differential zone (applied magnetic field > Brp and < Bop). Honeywell recommends allowing 10 µsec for output voltage to stabilize after supply voltage has reached 5 volts.
  • Page 3 (for reference only) mm/in (for reference only) mm/in NOTE: This product is sold in tape and reel form only, per EIA STD 481. There are 1,000 parts per reel. Honeywell • Sensing and Control 3 For application help: call 1-800-537-6945...
  • Page 4 Or call: 1-800-537-6945 USA/Canada 1-815-235-6847 International 1-815-235-6545 USA INTERNET www.honeywell.com/sensing info.sc@honeywell.com Sensing and Control www.honeywell.com/sensing Honeywell 11 West Spring Street Freeport, Illinois 61032 80079-5-EN IL50 GLO 104 Printed in USA Copyright 2004 Honeywell International Inc. All Rights Reserved.