S10:
10g, 1ips, 20mils
S11:
5g, 0.5ips, 10mils
S12:
Off = 0-5Vdc Output, On = 0-10Vdc Output
Internal DIP Switch Setting
The Internal DIP Switch of the 682 Series must be configured for the Full Scale Output of the ICP
connected to it. This is accomplished by removing the front cover and sliding the PC Board out of the Signal
Conditioner. Once removed, the DIP switch should be configured per one of the conditions in the following table.
Range Setting
S1
5g RMS
ON
5g Peak
ON
10g RMS
ON
10g Peak
ON
20g RMS
ON
20g Peak
ON
0.5 in/sec RMS
OFF
0.5 in/sec Peak
OFF
1.0 in/sec RMS
OFF
1.0 in/sec Peak
OFF
2.0 in/sec RMS
OFF
2.0 in/sec Peak
OFF
10 mils p-p
OFF
20 mils p-p
OFF
40 mils p-p
OFF
Filter Module Location
The Filter Modules are utilized to set the cutoff frequency of the internal band pass filter circuit. The 682 Series
comes standard with Modules preinstalled. If a different cutoff frequency is desired, the preinstalled module can
be removed by simply pulling it out of the MOD socket, and replacing it with a different module. The module is
labeled with the type of filter, Low Pass or High Pass, and the cutoff frequency. Module location is as follows:
Warning:
Do not make any adjustments to the internal potentiometers. These potentiometers are used for
factory calibration and adjusting them will require return of the 682 Series unit to the factory for recalibration.
S2
S3
S4
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
S12
S12
Note: Factory Default Setting is 1.0in/sec Peak, 0-5Vdc Output
MOD1:
Low Pass (LP) Filter Module Location
MOD2:
High Pass (HP) Filter Module Location
S5
S6
S7
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
0-5Vdc Output
ON
0-10Vdc Output
®
Sensor
S8
S9
S10
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
PAGE 10
S11
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF