Model 682B03/477A05 ICP® Vibration Transmitter Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: imi@pcb.com Web: www.imi-sensors.com...
Page 2
Service, Repair, and Return Policies and Instructions The information contained in this document supersedes all similar information that may be found elsewhere in this manual. also good practice to recalibrate after Service – Due to the sophisticated exposure to any severe temperature nature of the sensors and associated extreme, shock,...
Page 3
list(s) accompanying the shipment. A complete list of distributors and offices detailed account of the nature of the found www.pcb.com. problem(s) being experienced with the Customers within the United States may equipment should also be included contact their local sales representative inside the package(s) containing any factory customer...
Introduction ® The 682 Series is a 4-20mA Din Rail Signal Conditioner designed to interface with IMI Sensor’s ICP Accelerometer. Acceleration, Velocity, or Displacement can be converted to a 4-20mA signal by simple DIP Switch selection internal to the Din Rail enclosure. An additional standard feature of the 682 Series is the ability to convert the temperature output from an accelerometer (when equipped) to 4-20mA.
General Features ® External transmitters, signal conditioners, and ICP power supplies can be eliminated by direct connection of the sensor to the Din Rail Signal Conditioner. Optional 500Vdc Input to Output Electrical Isolation. Selectable 24Vdc Unregulated, 18Vdc regulated, 4mA excitation to power sensor ...
The 682 Series is designed to be mounted on a 35mm Din Rail. Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils. IMI Sensors recommends mounting the 682BX3 in a type NEMA 4 enclosure to protect the electronics from contamination.
Page 11
Connector and Pinout Diagram The 682 Series uses plug-in type screw terminal connectors for all input and output connections. Strip off 8mm of insulation from the connection wire ends. Using a screwdriver, remove the terminal block from the enclosure in either the up or down direction, terminate the wire in the correct location. Do not exceed a torque of 0.5Nm.
Page 12
Pin Descriptions: DC Power – Pins 1 to 3: Pin 1 +Power Pin 2 -Power/Common Pin 3 Earth Ground ® Accelerometer – Pins 4 to 6: Pin 4 Shield ® Pin 5 + ICP Accelerometer ® Pin 6 - ICP Accelerometer Temperature Sensor –...
Page 13
Typical Wiring Diagram 682 Series Signal 682A01 Conditioner Power Power Supply Supply Signal Conditioner PAGE 8...
To Maintain Conformance, Earth Ground, Power Supply Common, and I/O Shields must be connected together. Note: If using the 682 Power Supply, mount the 682 Signal Conditioner to the left of the power supply with a recommended minimum separation distance of 4” where applicable. Configuring the 682 Series Internal PC Board Diagram The Internal PC Board Diagram shows...
Page 15
S10: 10g, 1ips, 20mils S11: 5g, 0.5ips, 10mils S12: Off = 0-5Vdc Output, On = 0-10Vdc Output Internal DIP Switch Setting ® The Internal DIP Switch of the 682 Series must be configured for the Full Scale Output of the ICP Sensor connected to it.
Page 16
Sensor Power Jumper Configuration: (Factory Default) Note: If there is no DC bias on the input signal, this will trigger the Open/short detection which subtracts 4mA from output PAGE 11...
Warning 1 – ESD sensitivity The power supply/signal conditioner should not be opened by anyone other than qualified service personnel. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid injury. Warning 2 –...
ESD considerations should be made prior to performing any internal adjustments on the equipment. Any piece of electronic equipment is vulnerable to ESD when opened for adjustments. Internal adjustments should therefore be done ONLY at an ESD-safe work area. Many products have ESD protection, but the level of protection may be exceeded by extremely high voltage.
Warranty IMI instrumentation is warranted against defective material and workmanship for 1 year unless otherwise expressly specified. Damage to instruments caused by incorrect power or misapplication, is not covered by warranty. If there are any questions regarding power, intended application, or general usage, please consult with your local sales contact or distributor.
Customer Service IMI, a division of PCB Piezotronics, guarantees Total Customer Satisfaction. If, at any time, for any reason, you are not completely satisfied with any IMI product, IMI will repair, replace, or exchange it at no charge. You may also choose, within the warranty period, to have your purchase price refunded.
Page 21
Model Number Revision: B ICP® VIBRATION TRANSMITTER 682B03 ECN #: 47113 Performance ENGLISH OPTIONAL VERSIONS Channels Optional versions have identical specifications and accessories as listed for the standard model except where noted below. More than one option may be used.
Page 22
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. DIM .44 WAS .50 45450 4.47 [113.6] .44 [11.2] .890 [22.60] POWER/ FAULT ICP OUTPUT...
Need help?
Do you have a question about the 682B03 and is the answer not in the manual?
Questions and answers