Download Print this page

AMC soutdoor L Installation Instructions Manual page 8

Double pir outdoor detector

Advertisement

Remove the board, making a hole in the back of the upper cover for the cable to pass through in a suitable installation
position. Make another 2 holes to attach the sensor to the wall. We recommend using anchors that are no smaller
than 3 mm.
Screw for Anti-removal system - Fig.1
Once the cable and wall attachment holes have been made, take the measurement to attach an anchor (3 mm) to the
anti-removal system. (see above fig.1 and fig.2)
Then attach the bottom and re-close, taking into account the positioning mentioned previously.
Note: remember that the distance between the board and the base is 13.5 mm. Space reserved for the proper
positioning of the cable feeder or any piping to be inserted.
Using the bracket
You can use the bracket included in the package for attaching it to the wall. The back of the cover is ready for attach-
ment of the bracket and for the passage of the cables inside it. You can see how it should be used in the figure. In case
of use of the bracket, for the closure of the anti-removal tamper mount the specific screw, in the seat shown in Fig.1.
bracket
www.amcelettronica.com
A
B
C
D
Bottom of the detector
soutdoor L
Screw for Anti-removal system - Fig.2
Detector + bracket
Installation Instructions

Advertisement