AMC soutdoor L Installation Instructions Manual page 2

Double pir outdoor detector

Advertisement

description of terMinaLs and dip-sWitch
+/-
aLarM
taMper no
Led
dip 1
dip 2
dip 3
dip 4
EOL resistor jumpers
Dip switches
height adjustment
board
Installation
Place the sensor at a height of between 1 m and 2m. Important: placement should be chosen depending on the lens
used. Read the chapter LENSES to understand how to use them.
Use the dip switch for setting the sensor.
The Dip 4 is used when the installing condition are diificult. Eg. when there are many trees and plants, or when the size
of the animals are rather large (over 25kg).
Note: in the presence of large animals use the horizontal curtain lens in the down PIR, if is necessary move the board
of the sensor like in figure.
www.amcelettronica.com
Power supply 13.8Vcc
solid state relay 100 mA - 40 V - 2.5 -16 Ω
Tamper (N.C.) anti opening and anti removal 30vcc a 0.5A
Walk test led (1 short flash for one of 2 PIR detetction - long flash for alarm)
ON = led enabled OFF = disabled
ON = 12mt OFF = 6mt
ON = 2 pulse OFF 1 = pulse
ON = Noise/pet enabled
soutdoor L