Machine Operation
Break-away Floor Tool
The floor tool design incorporates a break-away feature.
Allowing it to safely disengage from its mounting should it become
caught on an obstruction, during forward machine movement.
To re-attach the blade to its holder. First loosen the retaining
knobs on the floor tool body and slide onto the holding bracket.
Tighten retaining knobs to finger tight.
!

Machine In Use

To operate, set water flow rate tap, lower brush deck, lower the floor tool, press the vacuum / water switches, pull brush On/Off trigger.
The waste water is then retrieved by the suction floor tool.
Overlap each scrubbing path by 10cm to ensure an even clean.
Do not operate the machine on inclines that exceed (2%), when full.
On heavily soiled floors use a 'double scrub' technique.
First pre-scrub the floor with the floor tool in the raised position, allow the chemical time to work then scrub the area a second time
with the floor tool lowered.
If streaking occurs wipe floor tool blades clean.
NOTE: Care must be taken to reduce speed when cornering or when manoeuvring around obstacles
10
www.numatic.co.uk
ALWAYS ENSURE THAT THE FLOOR IS PRE-SWEPT
AND RELEVANT SAFETY SIGNS ARE DISPLAYED.
!