SiBE12-522
Step
5
Take off the putty, and
remove each
thermistor.
6
Remove the wire
harness.
Removal Procedure
Procedure
Outdoor Unit (50 / 52 / 58 / 68 / 75 Class)
Points
Place the thermistor so that
its end comes up to the end
of the presser spring.
Be careful not to lose the
presser spring for the
discharge pipe
S90:
Outdoor air thermistor
Heat exchanger thermistor
(Gray)
Discharge pipe thermistor
(Black)
S92:
Gas pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Brown)
Room D (Red)
S93:
Liquid pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Yellow)
Room D (Blue)
thermistor.
(Blue)