Download Print this page
Avaya ERS4826GTS Setup
Avaya ERS4826GTS Setup

Avaya ERS4826GTS Setup

Ers4850 series

Advertisement

Quick Links

Ethernet Switch Setup
Avaya ERS4850 Series
and ERS4850GTS-PWR+)
Firmware used: 5.8.0.1

Configuring the Switch

Assign an IP address, enable the optional web interface, and assign
QoS
1. Using a standard network switch console or "rollover" cable, connect the serial port on the
PC, or a USB-to-serial adapter, to the console port on the front of the switch.
2. Open a terminal emulator such as HyperTerminal or PuTTY and connect to the switch
using the following serial settings: 9600, N, 8, 1; no flow control.
If the switch does not respond by initiating a terminal session, try turning it off and on again.
As the switch boots up, the terminal emulator window should start displaying log
messages.
3. When the AVAYA logo appears, it will also display a status area indicating the switch
model, hardware version, firmware version, and the software version.
4. Press Ctrl+Y. A prompt showing the switch model number will appear—for example,
4850GTS-PWR+> will appear. (Other models will display accordingly; for this setup guide,
we will use the 4850GTS-PWR+ as an example.)
5. Type enable and then press Enter.
6. The prompt will change to 4850GTS-PWR+#
Type
configure terminal
and press Enter.
7. The message "Enter configuration commands, one per line. End with CNTL/Z." will appear,
followed by the configuration-mode prompt, 4850GTS-PWR+(config)#
The next step is to configure the switch's intended IP address and subnet. Type
ip address xxx.xxx.xxx.xxx yyy.yyy.yyy.yyy
Revision 1.1—21 January 2016
(Models ERS4826GTS, ERS4826GTS-PWR+, ERS4850GTS,
Software used: v5.8.1.029
for Q-SYS

Advertisement

loading

Summary of Contents for Avaya ERS4826GTS

  • Page 1: Configuring The Switch

    As the switch boots up, the terminal emulator window should start displaying log messages. 3. When the AVAYA logo appears, it will also display a status area indicating the switch model, hardware version, firmware version, and the software version. 4. Press Ctrl+Y. A prompt showing the switch model number will appear—for example, 4850GTS-PWR+>...
  • Page 2 VLANs, so it often would not be appropriate to apply them to the entire switch. If a port uplinks to another Avaya switch, for example, it is better to let them honor their own IP precedence. In the commands below substitute the port number or numbers where it says “port number(s)”;...
  • Page 3 (or write mem) and press Enter. 12. The switch is now correctly configured to properly prioritize Q-SYS traffic in an Avaya enterprise QoS environment. Notes: How to set the switch to factory default configuration If you have “Enable” access: 1.
  • Page 4 2. Turn the switch off and on again to reboot it. 3. When the first line of the diagnostic tests appears, press Ctrl+C. 4. A menu will appear listing a number of options. Press I to initialize the switch and load its default settings into its configuration.

This manual is also suitable for:

Ers4826gts-pwr+Ers4850gtsErs4850gts-pwr+