5.2. IPSC-Series

On the devices of the IPSC-series, there are 4 status LEDs on the front panel:
IPSC1
PWR
ERR
STR
ARM
Table 23: IPSC - Identification of status LEDs on different models
When powering the device, POWER (green) and STROBE (yellow) LEDs are constantly ON,
and the FAULT (red) LED is flashing for 5 seconds. After the startup process is completed, only
the POWER (green) LED stays persistently ON.
The different LED status are shown in Table 24.
Type
POWER (green) LED
Solid on
FAULT (red) LED
Flashing in specific intervals
Flashing (in combination with STROBE (Yellow) LED)
STROBE (yellow) LED
Flashing
Solid on
ARMED (yellow) LED
Solid on
5.2.1.

Ethernet Status

The Ethernet connector provides a yellow and a green LEDs, where the green LED indicates
link, the yellow one activity.
Green LED (left)
OFF
Solid on
Yellow LED (right)
OFF
Flashing
Identifier
IPSC2
IPSC4
P
POWER
E
FAULT
S
STROBE
A
ARMED
Status
Controller is powered
System has a failure
Controller is starting up, setting controller's IP address,
updating firmware. The controller is in reboot mode
Indicates the pulse coming from the IPSC's output. The
duration of the LED being turned on depends of the
pulse length
The controller is either in Continuous or External Switch
mode. IPSC is driving outputs with continuous currents
Indicates voltage on output (ready for triggering pulses
or in continuous mode)
Table 24: IPSC - Status LEDs and description
Status
No link
Link on / Ethernet link exist
Status
No activity
Indicates ongoing activity
Table 25: IPSC Ethernet status LED
27
Color
Type
Green
POWER
Red
FAULT
Yellow1
STROBE
Yellow2
ARMED
SMARTEK Vision | User Manual – LED Strobe Controller Family | Doc. v2.1.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipsc2Ipsc4Hpsc1hpsc4

Table of Contents