3.0 Installation of energy calculator

Make sure the energy calculatorv is installed sufficiently far away
from possible sources of electromagnetic interference (switches,
electric motors, fluorescent lamps, etc...)
The energy calculator should be installed in an accessible position
for service and operating personnel.
Initial operation is to be carried out and recorded after installation.
For medium temperatures of more than 90°C or if T
(for application as cooling meter or heat meter with cooling tariff ),
the calculator must be removed from the flow sensor and installed
a sufficient distance away from heat sources.
A wall holder (supplied with meter) or a space holder (optional) is
available for this purpose.
2
DEN-SMT/PL
INFOCAL 8
.
< T
water
T: 5 ... 90°C
T
> T
water
ambient
ambient
wall mounting
VI.SH.L1.02
T: 5 ... 130 / 150°C
T
< T
water
ambient
space holder