▶ Identify the piping for hot and cold water, in order to avoid
a possible swop (FIg. 6).
2
Fig. 6
[1] Cold water inlet (right hand side)
[2] Hot water outlet (left hand side)
DANGER:
▶ Install a safety valve at the water inlet of
the appliance ( Fig. 7).
If the pressure at the cold water inlet is
superior to that of 80% of the maximum
pressure of the appliance at, ie: 6,4 bar,
install a reducing valve (FIg. 7).
The safety valves will trigger every time the
water pressure in the appliance is superior to
that of 6,4 bar, for which it will be necessary
to foresee a way to channel the draining of
the water.
NOTICE:
NEVER OBSTRUCT THE PURGE OUTLET OF
THE SAFETY VALVE.
Never install any accessory between the
safety valve and the cold-water inlet (right
hands side) of the appliance.
Tronic 1000 T
1
6720643873-04.1V
Installation (only for authorized installers) | 75
▶ Use the appropriate connection accessories to do the
hydraulic connection to the appliance.
1
2
1
Fig. 7
Water connection
[1] Galvanic insulator
[2] Hot water outlet
[3] Safety valve
[4] Drain connection
[5] Cut off valve
[6] Reduction valve
[7] Anti-reduction valve
[8] Connection to the water line
In order to avoid problems caused by sudden
pressure changes, we recommend the
installation of a anti-reduction valve at the
appliance (Fig. 7, [7]).
In the case of freezing:
▶ Switch off the appliance.
▶ Purge the appliance ( chapter 5.4).
5
6
7
8
3
4
6720643873-05.1V
6 720 801 512 (2015/05)