BOREAL® Thermolec® Plenum Heater Connections
2005 Boreal Geothermal Inc.
Electrical Connection to a BOREAL®
Connect the proper electrical supply with a suit-
able breaker to the main terminal block shown.
("A" at left)
Using 2 conductors in a length of 18-4 thermo-
stat wire, Connect "I" and "1" in the control
section of the heat pump's electrical box to "I"
and "1" terminal strip in the plenum heater as
shown.
Using the remaining 2 conductors, connect "F"
and "F" in the heat pump's electrical box to "F"
and "F" in the plenum heater.

Thermostat Operation

The BOREAL® heat pump comes supplied with a
2-stage heating / 1-stage cooling auto change-over
digital thermostat.
The heat pump is already prewired for this stat and
requires only the connections mentioned above for
full operation.
The thermostat operates the heat pump as the first
stage of heat bringing the electric backup on only if
required. There is a 2° differential between the first
and second stage of heat. The thermostat automati-
cally changes between heating and cooling as re-
quired by the building.
www.boreal-geothermal.com

Heat Pump

30