Bard QH242 Installation Instructions Manual

Qtec series packaged heat pump
Table of Contents

Advertisement

Quick Links

INSTALLATION
INSTRUCTIONS
Bard Manufacturing Company
Bryan, Ohio 43506
Since 1914 . . . Moving ahead, just as planned.
QTEC SERIES
PACKAGED HEAT PUMP
Models:
QH242
QH362
QH482
QH302
QH422
QH602
MIS-1554
Manual:
2100-379
Supersedes:
File:
Vol II Tab 14
Date:
12-01-00
© Copyright 2000

Advertisement

Table of Contents
loading

Summary of Contents for Bard QH242

  • Page 1 PACKAGED HEAT PUMP INSTALLATION Models: INSTRUCTIONS QH242 QH302 QH362 QH422 QH482 QH602 MIS-1554 Manual: 2100-379 Bard Manufacturing Company Supersedes: Bryan, Ohio 43506 File: Vol II Tab 14 Date: 12-01-00 Since 1914 . . . Moving ahead, just as planned. © Copyright 2000...
  • Page 2: Table Of Contents

    CONTENTS Getting Other Information and Publications Description of Standard Equipment ....... 18 For more information, contact these publishers: ..1 Optional CFM (QH361QH421and QH481 Only) .... 18 Important Installer Note ..........18 General Information Phase Monitor ..............18 Model Nomenclature .......... 2 Three Phase Scroll Compressor Start Up Shipping Damage ............
  • Page 3: Getting Other Information And Publications

    GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the air FOR MORE INFORMATION, CONTACT conditioner or heat pump. You can usually find these at THESE PUBLISHERS: your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard.
  • Page 4: Qt Ec Model Nomenclature

    Series General Information MODEL NOMENCLATURE 2 – A MODEL NUMBER | FILTER OPTIONS COIL OPTIONS QH - QT Model 0Z - 0KW X - 1 Inch Fiberglass X - Standard 05 - 5KW (Standard) F - 2 Inch Fiberglass 06 - 6KW CAPACITY | 09 - 9KW P - 2 Inch Pleated...
  • Page 5: Table 2 Electrical Specifications

    TABLE 2 ELECTRICAL SPECIFICATIONS " " & Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75° C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity”...
  • Page 6: Table 2A Electrical Specifications

    TABLE 2A ELECTRICAL SPECIFICATIONS (continued from Page 3) " " & Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75° C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity”...
  • Page 7: Figure 1 Unit Dimensions

    FIGURE 1 UNIT DIMENSIONS MIS-1572...
  • Page 8: Shipping Damage

    FIGURE 2 SHIPPING DAMAGE AIR SEAL UNDER QT UNIT Upon receipt of equipment, the carton should be checked for external signs of shipping damage. The skid must remain attached to the unit until the unit is ready for installation. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.
  • Page 9: Handling Unit After Removal From Skid

    HANDLING UNIT AFTER REMOVAL The wheels of the unit must be locked. If the wheels were allowed to roll, the unit could roll off the cart. FROM SKID The unit should always be carted from the left side. This is the side where the compressor is located. See WARNING Figure 4.
  • Page 10: Figure 5 Installation With Free Blow Plenum

    FIGURE 5 INSTALLATION WITH FREE BLOW PLENUM CEILING 8 FT. - 6 IN. MINIMUM RECOMMENDED 8 FT. - 4 IN. CEILING HEIGHT MIS-1574 FLOOR FIGURE 6 DUCTED APPLICATION SUSPENDED CEILING DUCT FIXED CEILING 20 IN. MINIMUM DUCT FLANGE 12 IN. MINIMUM 2 IN.
  • Page 11: Duct Work

    For hot water coil option a QPBHWxx-F for free blow DUCT WORK or QPBHWxx-D for ducted airflow is used Any heat pump is more critical of proper operating When used with a ducted supply, a QCX Cabinet charge and an adequate duct system than a straight air Extension can be used to conceal the duct work above conditioning unit.
  • Page 12: Fresh Air Intake

    CONDENSATE DRAIN FRESH AIR INTAKE There are two drain connections on the unit. The side This unit is equipped with a fresh air damper assembly. drain is located on the bottom right side of the unit. The damper blade is locked in the closed position when The rear drain is an optional drain, and is located on the the unit is shipped from the Factory.
  • Page 13: Service Light

    SERVICE LIGHT FIGURE 11 REAR DRAIN (TOP VIEW) The unit is equipped with a service light which signals DRAIN LINE the user that service is required. The light is located in the upper control panel and is visible only when the hinged service/filter access door is open.
  • Page 14: Installation Instructions

    INSTALLATION INSTRUCTIONS alignment to the mounting brackets. This unit MOUNTING THE UNIT must be level from side to side. If adjustments When installing a QT unit near an interior wall on the are necessary, shim up under the rollers with left side, a minimum of 8 inches is required;...
  • Page 15: Wiring - Main Power

    CONTROL BLOCK The subbase of the thermostat is factory wired to the front panel of the unit. Compatible for use with Bard INDOOR BLOWER CS2000 Controller and Energy Recovery Ventilator. The Climate Control Option D is an electronic, DEHUMIDIFICATION programmable thermostat.
  • Page 16: Figure 15 Thermostat Plug Terminals

    TABLE 4 WALL THERMOSTATS AND SUBBASE COMBINATIONS c i t t i s FIGURE 15 THERMOSTAT PLUG TERMINALS BLOWER MOTOR P2 AND P4 LOW VOLTAGE PLUG (VIEWED FROM PIN END) (VIEWED FROM PIN END) MIS-1285 Manual 2100-379 Page...
  • Page 17: Figure 16 Thermostat Wiring Diagram "X" Option

    FIGURE 16 REMOTE THERMOSTAT WIRING DIAGRAM “X” THERMOSTAT OPTION T874N1024 T874R1129 T8511 1F94-80 LVTB Q674F1261 Q674L1181 24VAC HOT 1ST STAGE HEAT (COMP) CHECK SYSTEM LIGHT REVERSING VALVE 2ND STAGE HEAT EMERGENCY HEAT 24VAC COM 1ST STAGE COOL (COMP OR ECON) BLOWER 2ND STAGE COOL (COMP ON ECON EQUIPPED UNITS ONLY)
  • Page 18: Figure 17 Thermostat Wiring Diagram "A" Option

    FIGURE 17 REMOTE THERMOSTAT WIRING DIAGRAM “A” THERMOSTAT OPTION T8511 MIS-1293 Manual 2100-379 Page...
  • Page 19: Figure 18 Thermostat Wiring Diagram "D" Option

    FIGURE 18 REMOTE THERMOSTAT WIRING DIAGRAM “D” THERMOSTAT OPTION 1F94-80 MIS-1292 Manual 2100-379 Page...
  • Page 20: Start Up

    START UP DESCRIPTION OF STANDARD IMPORTANT INSTALLER NOTE EQUIPMENT For improved start-up performance, wash the indoor coil with a dishwasher detergent. Solid State Electronic Heat Pump Control Provides efficient 30 minute defrost cycle. A thermistor sensor and speed up terminal for service along with a 10 PHASE MONITOR minute defrost override are standard on the electronic heat pump control.
  • Page 21: Service Hints

    f. If unit is attached to duct work, remove upper All three phase scroll compressors used in the QT cabinet extension by removing the top center series are wired identically internally. As a result, once screw only from the cabinet side panel. the correct phasing is determined for a specific system or installation, connecting properly phased power leads g.
  • Page 22: Vent Options

    VENT OPTIONS 2. The power connectors for the CRV (located on the right side of the unit) must be disconnected. BAROMETRIC FRESH AIR DAMPER (Standard) Squeeze the tabs on the sides of the connector and pull straight out. Unplug both of the Before starting, make sure the power has been turned connectors.
  • Page 23: Figure 19 Fresh Air Damper Removal

    FIGURE 19 FRESH AIR DAMPER REMOVAL MOUNTING SCREW BLANK OFF PLATE MIS-1578 Manual 2100-379 Page...
  • Page 24: Figure 20 Qerv Removal

    FIGURE 20 QERV REMOVAL POWER CONNECTORS MOUNTING SCREWS LOWER BLOWER ASSEMBLY POWER CONNECTOR FRONT FILL MIS-1039 Manual 2100-379 Page...
  • Page 25: Sequence Of Operation

    SEQUENCE OF OPERATION OPTIONAL CLIMATE CONTROLS SEQUENCE OF OPERATION Cooling – Circuit R-Y makes the thermostat pull in the compressor contactor starting the compressor and The Climate Control Option A is an electronic, non- outdoor motor. The G (indoor motor) circuit is programmable manual or auto changeover thermostat.
  • Page 26: Defrost Cycle

    FIGURE 21 HEAT PUMP CONTROL BOARD MIS-973 DEFROST CYCLE If some abnormal or temporary condition such as a high wind causes the heat pump to have a prolonged defrost The defrost cycle is controlled by temperature and time cycle, the heat pump control will restore the system to on the solid state heat pump control.
  • Page 27: Troubleshooting

    TROUBLESHOOTING TABLE 5 TROUBLESHOOTING t i u , t i t i n . l o a t l n i l . l o c t i c t i c t i c t i a t l .
  • Page 28: Solid State Heat Pump Control Troubleshooting Procedure

    SOLID STATE HEAT PUMP CONTROL CHECKING TEMPERATURE SENSOR TROUBLESHOOTING PROCEDURE 1. Disconnect temperature sensor from board and from outdoor coil. 1. Turn on AC power supply to indoor and outdoor units. 2. Use an ohmmeter and measure the resistance of the sensor.
  • Page 29: Figure 24 Heat Pump Control Board

    FAN BLADE SETTING DIMENSIONS REFRIGERANT CHARGE Any service work requiring removal or adjustment in The correct system R-22 charge is shown on the unit the fan and/or motor area will require that the rating plate. Optimum unit performance will occur with dimensions in Table 7 be checked and blade adjusted in a refrigerant charge resulting in a suction line or out of the motor shaft accordingly.
  • Page 30: Pressure Charts

    TABLE 10 COOLING PRESSURE (All Temperatures in Degrees F) " Low side pressure ± 2 psig High side pressure ± 5 psig Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct operating charge being in the system, the charge should be removed, system evacuated and recharged to serial plate instructions.
  • Page 31: Table 11 Heating Pressure

    TABLE 11 HEATING PRESSURE (All Temperatures in Degrees F) Refer to notes following Table 10 Manual 2100-379 Page...
  • Page 32: Figure 24 Fan Blade Setting

    TABLE 12 OPTIONAL ACCESSORIES e l l ) s l ) s l ) s l ) s l ) s l ) s l " 4 s t i " 4 s t i o l l o l l e t i i n i l l i...

This manual is also suitable for:

Qh362Qh422Qh482Qh602Qh302

Table of Contents