errors anD WarninGs. What theY mean.
no floW
Diagnosis: Insufficient water flow in the cell.
This could mean the circulation pump has ceased to function, or
the filter needs cleaning. The sanitizer output will be turned off at
this time.
checK minerals
Diagnosis: Mineral levels have dropped below the optimum amount,
this can sometimes be dependant on water temperature. Cold water
is less conductive and the warning light may activate in cold water.
Always maintain minerals at suitable levels. If the light should
activate and the water temperature is at swimming temperature, it
is recommended to add a bag of MagnaPool Minerals to the water.
Above 5000ppm is optimal if you don't know what your mineral level
is or how to test it, consult your local pool care professional.
checK PoWer suPPlY
Diagnosis: There could be a problem with the control centre. Turn
power off at the power point and consult your local pool care
professional.
cleaninG
Diagnosis: The cell is in the process of reversing polarity.
Wait approximately 5 minutes and sanitizer production should
resume as normal.