Adjustment - Kenwood RXD-V323 Service Manual

Hide thumbs Also See for RXD-V323:
Table of Contents

Advertisement

RXD-V323
FM SECTION
NO.
ITEM
AUTO STOP
1
LEVEL
MW SECTION
NO.
ITEM
1.
IF
LOW END
2.
TRACKING
HIGH END
3.
TRACKING
4.
VT
INSTRUMENTS CONNECTION
AC voltmeter
Oscilloscope
8

ADJUSTMENT

INPUT
OUTPUT
SETTING
SETTING
(A)
98.0 MHz MONO
1kHz, ±75kHz dev
30dBu (ANT input)
INPUT
OUTPUT
SETTING
SETTING
(D)
531 kHz 1 kHz,
30% MOD
60 dBu (ANT INPUT)
(D)
531 kHz 1 kHz,
30% MOD
30 dBu (ANT INPUT)
(D)
1602 kHz 1 kHz,
30% MOD
30 dBu (ANT INPUT)
Connect the DC
voltage meter to
TO TUNER UNIT
CN101, pin 9 (Lch)
pin 7 (Rch)
pin 8 (GND)
Distortion meter
(B)
TUNER
ALIGNMENT
SETTING
AUTO
98.0MHz
TUNER
ALIGNMENT
SETTING
(B)
531 kHz
(B)
531 kHz
(B)
1602 kHz
531 kHz
1602 kHz
TP1.
(A)
FM-MPX-SG
POLAR SG
FM-MPX-SG
(C)
AM-SG
(D)
ALIGN FOR
POINTS
Adjust SFR101 and
stop at the point
SFR101
where FLD801(
goes ON.
ALIGN FOR
POINTS
Maximum output
T102
(Minimum distortion)
T103
Maximum output
TC101
Maximum output
T104
VT=1.2V±0.05V
Check the
VT=7.3V±1.0V
ANTENNA
FM 75 Ω
AM
GND
Dummy antenna
FIG.
)
FIG.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-n323

Table of Contents