Cabela's 541836 Warning & Instruction Booklet page 7

Pellet grill and smoker
Table of Contents

Advertisement

Fig. 9
CLEAN-OUT PORT KNOB
1. Clean-out Port knob must be pushed in when grill is on. Make
sure pullout lock is pushed down and locks the knob to prevent
inadvertent opening of the clean-out port. See Fig. 10.
2. Lift pullout lock and pull clean-out port knob to empty ash into
ash cup. See Fig. 11.
3. See instructions for burner clean-out.
Fig. 10
WARMING RACK
COOKING GRATE
Fig. 11
ORT CLOSED
PROBE
1. Plug the Meat Probe into the Probe receptacle on the control
panel. Run the probe and wire through the probe access hole on
the side of the grill. See Fig 12.
2. See instructions for Meat Probe.
Fig. 12
PROBE
WARMING RACK
COOKING GRATE
WARMING RACK
COOKING GRATE
CLEANOUT PORT CLOSED
CLEANOUT PORT OPEN
PROBE HOLE
BURNER CLEAN-OUT
Before each use the burner should be cleaned out by lifting the
pullout lock and pulling the clean-out port knob on the right side
of the grill to open the burner clean-out. This will allow the ash
from previous use to fall into the cup under the grill. The cup
should be removed and emptied and then reinstalled before
each use.
Never Operate the Pellet grill without the
ash cup in place.
Make sure the burner clean-out port is
closed and locked before starting the grill.
Never open the burner clean-out port when
the grill is hot.
CLEANOUT PORT OPEN
After cleaning out the burner make sure to close the burner
clean-out by pushing the clean-out port knob in on the right side
of the grill. Make sure to lift the pullout lock and push the
clean-out port knob all the way in and lock in place with the
pullout lock. Every 50 hours of use, remove the grill grates, grease
tray, and heat deflector and clean the inside of the grill. If you
notice a lot of ash blowing around in the grill it is time to vacuum
it out.
FILLING THE AUGER TUBE
CAUTION: ONLY USE THE FEED SETTING WHEN HOPPER HAS RAN
OUT OF PELLETS. FEED SETTING IS NOT FOR NORMAL USE.
The first time you use your grill or any time the hopper has ran out
of pellets you will need to fill the auger tube. This simply means
you must fill the auger tube with pellets until pellets reach the
burner. This is done by turning the dial to the FEED position and
then holding in the bypass button for 3 seconds. This will turn the
auger on and the digital readout will display "FEED". The auger
will remain on for no more than 5 minutes. This is ample time for
the pellets to reach the burner. It is easiest to open the burner
clean-out by pulling the knob on the right side of the grill. Once
you hear pellets dropping into the cup you can close the
clean-out port by pushing the knob on the right side of the grill
and then select your cooking temperature. (Never operate grill
without the ash cup in place). Always make sure the burner
clean-out port is closed by pushing in the knob on the right side of
the grill before selecting any of the cook settings. Never open the
burner clean-out port when the grill is hot.
DANGER
CLEANOUT P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

541835

Table of Contents