7. ELECTRICAL DATA

7-1. Electrical Characteristics

1 - indoor unit in operation
Indoor Unit
Outdoor Unit
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
2 - indoor units in operation
Indoor Unit
Outdoor Unit
Performance at
Rating Conditions
Full Load Conditions Running Amps.
Rating Conditions
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
SAP – K91A ( 1)
SAP – CM1821A
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
SAP – K91A ( 2)
SAP – CM1821A
Running Amps.
A
Power Input
kW
A
Power Input
kW
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Outdoor Air Temperature 43°C D.B.
Indoor Unit
Fan Motor
Fan Motor
240V Single phase 50Hz
0.18
0.50
0.040
0.119
0.18
0.50
0.040
0.119
Indoor Unit
Fan Motor
Fan Motor
240V Single phase 50Hz
0.36
0.50
0.080
0.119
0.36
0.50
0.080
0.119
12
Outdoor Unit
Compressor
4.32
0.951
5.12
1.121
Outdoor Unit
Compressor
8.44
1.921
10.04
2.261
Complete Unit
5.0
1.11
5.8
1.28
Complete Unit
9.3
2.12
10.9
2.46