2 - indoor units in operation
Indoor Unit
SAP – K91A ( 2)
Outdoor Unit
SAP – CM1821A
240V Single phase 50Hz
RATING CAPACITY
EVAPORATOR
ENT. TEMP. °C
W.B.
D.B.
21
15
23
25
27
29
31
21
17
23
25
27
29
31
21
19
23
25
27
29
31
23
21
25
27
29
31
23
25
27
29
31
TC :
Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.
5.00 kW
OUTDOOR AMBIENT TEMP. °C
20
25
TC
5.04
4.82
CM
1.46
1.58
SHC
3.41
3.30
SHC
3.83
3.72
SHC
4.25
4.14
SHC
4.67
4.56
SHC
5.04
4.82
SHC
5.04
4.82
TC
5.41
5.17
CM
1.50
1.62
SHC
2.98
2.87
SHC
3.40
3.29
SHC
3.82
3.71
SHC
4.24
4.13
SHC
4.66
4.55
SHC
5.08
4.97
TC
5.75
5.50
CM
1.55
1.67
SHC
2.53
2.42
SHC
2.95
2.84
SHC
3.37
3.26
SHC
3.79
3.67
SHC
4.21
4.09
SHC
4.63
4.51
TC
6.10
5.83
CM
1.59
1.72
SHC
2.49
2.38
SHC
2.91
2.80
SHC
3.33
3.22
SHC
3.75
3.64
SHC
4.17
4.06
TC
6.47
6.19
CM
1.62
1.76
SHC
2.42
2.31
SHC
2.84
2.73
SHC
3.26
3.15
SHC
3.68
3.57
CONDENSER
30
35
4.60
4.38
1.69
1.81
3.19
3.08
3.61
3.50
4.03
3.92
4.45
4.34
4.60
4.38
4.60
4.38
4.94
4.70
1.74
1.86
2.76
2.65
3.18
3.07
3.60
3.49
4.02
3.91
4.44
4.33
4.85
4.70
5.25
# 5.00
1.79
1.92
2.31
2.20
2.73
2.62
3.14
3.04
3.56
3.46
3.98
3.88
4.40
4.29
5.57
5.30
1.84
1.97
2.27
2.16
2.69
2.58
3.11
3.00
3.53
3.42
3.95
3.84
5.90
5.57
1.89
2.03
2.20
2.08
2.62
2.50
3.04
2.92
3.46
3.34
9
40
43
4.11
3.79
1.91
2.02
2.95
2.79
3.37
3.21
3.79
3.63
4.11
3.79
4.11
3.79
4.11
3.79
4.42
4.07
1.97
2.08
2.52
2.36
2.94
2.78
3.36
3.20
3.78
3.62
4.20
4.04
4.42
4.07
4.70
4.33
2.03
2.14
2.07
1.91
2.49
2.33
2.91
2.75
3.33
3.17
3.75
3.59
4.17
4.01
4.98
4.58
2.09
2.20
2.04
1.88
2.46
2.30
2.88
2.72
3.29
3.14
3.71
3.56
5.21
4.85
2.14
2.26
1.95
1.82
2.37
2.24
2.79
2.66
3.21
3.08