Front Panel And Led Definitions - HPE Synergy 12Gb SAS Storage Maintenance And Service Manual

Hide thumbs Also See for Synergy 12Gb SAS Storage:
Table of Contents

Advertisement

Front panel and LED definitions

The front panel and LED layout shown in the following illustration is an example. Depending on your
specific model, the LEDs might be different.
Item
LED
Drawer status*
1
UID
2
Health status
3
Drive status (in
4
priority order)
Drawer power
5
*The drive drawer must be closed within five minutes after it is opened.
Status
Solid green
Flashing green
Flashing amber
Solid blue
Flashing blue
Off
Green
Flashing amber
Flashing red
Solid amber
Flashing amber
Flashing green
Solid green
Off
Green
Off
Definition
Drive drawer is closed
Drive drawer is open
Thermal warning, close the drive drawer
One or more drives are being located
Firmware flash in progress
No drives are being located
Normal operation
Degraded condition
Critical condition
One or more drives failed
One or more drives are predicted to fail
One or more drives are rebuilding or transforming
One or more drives are members of a logical drive
No drives are configured by a RAID controller
Storage module is in use, do not remove
Storage module is not in use, safe to remove
Component identification 31

Advertisement

Table of Contents
loading

Table of Contents