Diagnosis display
Abnormality/Protection control
Outdoor compressor overheating
F20
protection
IPM (power transistor) overheating
F22
protection
Outdoor Direct Current (DC) peak
F23
detection
F24
Refrigeration cycle abnormality
Cooling/Heating cycle changeover
F25
abnormality
F27
Pressure switch abnormality
F29
Low Discharge Superheat
F30
Water outlet sensor 2 abnormality
F32
Abnormal Internal Thermostat
Outdoor air temperature sensor
F36
abnormality
Indoor water inlet temperature sensor
F37
abnormality
Outdoor discharge pipe temperature
F40
sensor abnormality
F41
PFC control
Outdoor heat exchanger temperature
F42
sensor abnormality
F43
Outdoor defrost sensor abnormality
Indoor water outlet temperature sensor
F45
abnormality
Outdoor Current Transformer open
F46
circuit
Outdoor EVA outlet temperature sensor
F48
abnormality
Outdoor bypass outlet temperature
F49
sensor abnormality
Cooling high pressure overload
F95
protection
Note: * This error code is not applicable for this system.
Abnormality judgement
4 times occurrence within 30
minutes
3 times occurrence within 30
minutes
7 times occurrence
continuously
2 times occurrence within 20
minutes
4 times occurrence within 30
minutes
Continue for 1 min.
1 times occurrence within
2550 minutes
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
4 times occurrence within 10
minutes
Continue for 5 sec.
Continue for 5 sec.
Continue for 5 sec.
—
Continue for 5 sec.
Continue for 5 sec.
—
160
Primary location to verify
Compressor tank temperature sensor
Clogged expansion valve or strainer
Insufficient refrigerant
Outdoor PCB
Compressor
Improper heat exchange
IPM (Power transistor)
Outdoor PCB
Compressor
Insufficient refrigerant
Outdoor PCB
Compressor low compression
4-way valve
V-coil
Pressure switch
Discharge Temperature Sensor
Discharge Pressure Sensor
Pressure Switch
Outdoor PCB
Water outlet sensor 2 (defective or
disconnected)
Control panel PCB thermostat
Outdoor air temperature sensor
(defective or disconnected)
Water inlet temperature sensor
(defective or disconnected)
Outdoor discharge pipe temperature
sensor (defective or disconnected)
Voltage at PFC
Outdoor heat exchanger temperature
sensor (defective or disconnected)
Outdoor defrost sensor (defective or
disconnected)
Water outlet temperature sensor
(defective or disconnected)
Insufficient refrigerant
Outdoor PCB
Compressor low
Outdoor EVA outlet temperature sensor
(defective or disconnected)
Outdoor bypass outlet temperature
sensor (defective or disconnected)
Outdoor high pressure sensor
Water pump or water leakage
Clogged expansion valve or strainer
Excess refrigerant
Outdoor PCB