4-2 Adjustment
4-2-1 Service Instruction
■ Before Performing after Sales Services
1. Check if the measurement and test equipment is working properly.
2. Secure sufficient work space for disassembling the product.
3. Prepare a soft pad for disassembling the product.
■ Service adjustment item after replacement of Board
<If adjustment equipment is available>
① PDP Option of factory Mode → set the factory Data Type item as the suitable value of relevant model.
② Adjust Calibration of Factory Mode for each mode.
③ Adjust white Balance of Factory Mode.
<If adjustment equipment is not available>
① write down the value of hDMI white Balance of Factory Mode before replacing Board.
② PDP Option of factory Mode → set the factory Data Type item as the suitable value of relevant model.
③ Set the value of hDMI white Balance with the value written down before.