4.1 General cabling guidance

Cable types and length

It is important to use cables of the appropriate type and length
• Unless otherwise stated use only standard cables of the correct type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the correct quality and gauge. For example, longer
power cable runs may require larger wire gauges to minimize voltage drop along the run.

Routing cables

Cables must be routed correctly, to maximize performance and prolong cable life.
• Do NOT bend cables excessively. Wherever possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
• Protect all cables from physical damage and exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing twine. Coil any extra cable and tie it out of the way.
• Where a cable passes through an exposed bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or fluorescent lights.
Always route data cables as far away as possible from:
• other equipment and cables,
• high current carrying AC and DC power lines,
• antennae.

Strain relief

Ensure adequate strain relief is provided. Protect connectors from strain and ensure they will not pull
out under extreme sea conditions.

Cable shielding

Ensure that all data cables are properly shielded that the cable shielding is intact (e.g. hasn't been
scraped off by being squeezed through a tight area).