3-1-2.
Connection of Equipment
According to the specification for the input terminal (CAMERA
input, S VIDEO input, VIDEO input, or DV input), connect
measuring equipment as shown in Fig. 5-3-1, and make adjustment.
The input terminal is specified in ( ) of the signal column.
Any input terminal can be used unless otherwise specified.
To switch between CAMERA input, S VIDEO input, VIDEO input
and DV input, use the INPUT SELECT switch.
Pattern generator
MONITOR TV
NTSC: DSR-50
PAL : DSR-50P
When S VIDEO is specified
• When a pattern generator without
the Y/C separator terminal is used.
VTR with S VIDEO terminal (E-E mode)
VIDEO IN
VIDEO OUT
(75 Ω)
• When a pattern generator with
the Y/C separator terminal is used.
Pattern generator
Y OUT (75 Ω)
CHROMA
OUT (75 Ω)
DV
INPUT SELECT
switch
Note 1: In adjustments specifying for the S VIDEO input to be
used, using the VIDEO input would disable the product
specifications of this unit from being satisfied. Always
use the input signal specified.
Note 2: If adjustments are used with the VTR with the S video
output terminal as the signal source, the performance of
this unit may be affected by the VTR. Use a pattern gen-
erator with a Y/C separator terminal as much as possible.
S VIDEO OUT
When CAMERA is specified
Y OUT (75 Ω)
R-Y OUT (75 Ω)
B-Y OUT (75 Ω)
Pattern generator with the
COMPONENT OUTPUT terminal
Fig. 5-3-1
5-42
When VIDEO is specified
Pattern generator
VIDEO OUT
(75 Ω)
Regulated power supply
(14.4 ± 0.2 Vdc, 4A or more)