External Sump Alarm Sensor For Aurora Controls - Symphony Aurora WebLink Installation Manual

Hide thumbs Also See for Aurora WebLink:
Table of Contents

Advertisement

Aurora WebLink (AWL) Installation and Confi guration

External Sump Alarm Sensor for Aurora Controls

The Symphony/AWL System provides the infrastructure not only for status and fault notifi cation of the geothermal unit but also
sensors external to the heat pump. This is accomplished by using the exclusive Home Automation Inputs of the Aurora AXB board
and external sensors to provide the same e-mail/text notifi cation for technicians and consumers. This provides a powerful exten-
sion of the Symphony system to include monitoring of other critical home systems. One of these other sensors can be:
Sump Alarm WA01-Water (Sump) Alarm Sensor for Aurora Controls
This sensor provides a relay closure that can be used to trip a fault when moisture is present. This can be used as a pri-
mary sump alarm or simply a wet basement or signal a blown washing machine hose.
WA01-Water
(Sump) Alarm Sensor
The sensor can be added to any Aurora Advanced Control System (including both ABC and AXB) to monitor a sump pump.
The sensor can be connected to the Aurora Home Automation inputs (HA-1 or HA-2) of the AXB board. These will each
display an E23 and E24 code respectively when the alarm is active and when Symphony/AWL is installed will also produce
text/e-mail notifi cations for E23 or E24. The inputs should be confi gured for "Normally open" and the fault text for the
E23 or E24 can be selected by the technician using the AID Setup screens for the appropriate sensor installed. The "Fault
description text" is selectable so the users are aware of exactly which sensor is installed and faulting. These faults DO NOT
affect the operation of the heat pump and are simply passed through the Aurora controls to display on the thermostat and
pass through Symphony to the e-mail/text message notifi cation system for remote monitoring. This provides a powerful ex-
tension of the Symphony system to include monitoring of other critical home systems. The following diagram shows proper
wiring.
Water
Siren
(WA01)
13
AURORA WEBLINK (AWL) INSTALLATION GUIDE
AXB P4
IG2001EW

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aurora WebLink and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF