Hour Meter Range & Resolution
Hour Meter: 99,999.9 Total Hours, 0.1 hours resolution.
Maintenance Monitor: 999 Total Hours (countdown), 1 hour resolution

Panel Cutout

92 (+ 0.8/-0.0) mm x 138 (+1.0/-0.0) mm
1.3 Environmental
Operating Temperature Range:
Storage Temperature Range:
Thermal Cycling
(Applicable To Enclosed Units Only):
Thermal Shock
(Applicable To Enclosed Units Only):
Humidity
(Applicable To Enclosed Units Only):
Shock
(Applicable To Enclosed Units Only):
Vibration
(Applicable To Enclosed Units Only):
IP Ratings
(Applicable To Enclosed Units Only):
Curtis enGage™ IV Manual
-40°C to +70°C
-50°C to +90°C as per SAE J1455,
section 4.1.1.5.
As per SAE J1455 section 4.1.3.1.
to +80°C
As per SAE J1455 section 4.1.3.2.
to +80°C
95% RH (non-condensing) at +38°C
as per SAE J1455, section 4.2.3.
SAE J 1378 March 83. Amplitude
44 - 55g, half sine, 9-13 ms duration.
SAE J 1378 March 83. Double
amplitude of 1.53 mm with
frequency sweep from 10-80-10 Hz
(20 g max.) at intervals of 1 minute.
Face sealed to IP65.