General
Problem
No Display
BDI Function
Problem
No Display
Stays At FULL
Will Not Reset
Resets Without
Charging Battery
Empty Too Soon
page 9
4.0 Trouble-shooting
Possible Cause
V+ (keyswitch) voltage not present at J1-13.
Battery voltage too low. Battery terminals
not connected.
Possible Cause
Terminals Not Connected.
Improper Voltage – Check Pin J1-17
Instrument voltage range selected does not
match battery voltage.
Range Select V+ connected to wrong
terminal.
Instrument voltage does not match battery
voltage.
Battery not fully charged.
Battery may be defective.
Not connected directly to battery terminals.
Range Select V+ connected to wrong
terminal.
Instrument voltage does not match battery
voltage.
Terminals not connected directly to battery.