Mitsubishi Electric PUZ-HA30NHA5 Service Manual page 76

Mr. slim split-type, heat pump air conditioners
Hide thumbs Also See for PUZ-HA30NHA5:
Table of Contents

Advertisement

(2) Functions available when setting the unit number to 01-03 or AL (07 in the case of the IR wireless remote controller)
• When setting functions for an indoor unit in an independent system, set the unit number to 01 referring to 4 setting the
indoor unit number.
• When setting functions for a simultaneous twin indoor unit system, set the unit number to 01 to 03 for each indoor
unit in case of selecting different functions for each unit referring to 4 setting the indoor unit number.
• When setting the same functions for an entire simultaneous Twin-indoor unit system, set refrigerant address to AL
(07 in the case of the IR wireless remote controller) referring to 4 setting the indoor unit number.
Function
100h
Filter sign
2500h
"Clean the filter" indicator is not displayed
Air flow
Quiet
( Fan speed )
Standard
High ceiling
4 directions
No.of air outlets
3 directions
2 directions
Optional high efficiency
Not supported
filter
Supported
Vane setting
No vanes (Vane No.3 setting: PLA only)
Vane No.1 setting
Vane No.2 setting
Not supported
Optional humidifier
( PLA only )
Supported
No.1 setting (TH5: 75−82˚F [24–28:])
Vane differential setting
in heating mode
No.2 setting (Standard, TH5: 82–90˚F [28–32:])
( cold wind prevention )
No.3 setting (TH5: 90–100˚F [32–38:])
Swing
Not available Swing
Available
Available
Set temperature in heating
mode ( 7.2 ˚F [4:] up ) *1
Not available
Extra low
Fan speed when the
Stop
heating thermostat is OFF
Keeping fan speed set by remote controller
Keeping fan speed set by remote controller
Fan speed when the
cooling thermostat is OFF
Stop
Detect
Detection of abnormality of
the pipe temperature ( P8 )
Neglect
1
*
PKA-HA(L)/KA(L): 3.6-F [2:]) up
Mode No.11
Setting No. Settings
1
Vane No.3 setting
2
Vane No.1 setting
3
Vane No.2 setting
* Be careful of the smudge on ceiling.
OCH607
Settings
Wired remote controller
(RF thermostat)
}
PLA-BA
Wave air flow
PLA-BA
Less smudging
( Downward position than the standard )
Standard
Less draft *
( Upward position than the standard )
Mode No.
4-Way
Setting No.
cassette
PLA-BA
1
07
2
(107)
3
1
08
2
(108)
3
1
09
2
(109)
3
10
1
(110)
2
1
11
2
(111)
3
13
1
(113)
2
1
14
2
(114)
3
23
1
(123)
2
24
1
(124)
2
1
25
2
(125)
3
27
1
(127)
2
28
1
(128)
2
No vane function
Standard
Less draft *
( Upward position than the standard )
76
: Initial setting ( Factory setting )
- : Not available
Ceiling
Wall mounted
Suspended
PKA-KA
PKA-HA
PCA-KA
PKA-HAL
PKA-KAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PCA-KA