Press the scroll
button again to advance to the next
regeneration cycle.
Refill
Brine preparation
Brine draw/slow rinse
8. Press the scroll
button again; the display will show:
Regen:Dlyd/Immd
2:00
Press the up
or down
regeneration mode:
 Dlyd/Immd: when the remaining capacity equals
the reserve capacity, a delayed regeneration is
started at the programmed time of regeneration;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an immediate regeneration is started.
 Immediate: when the remaining capacity equals
0, an immediate regeneration is started.
 Delayed: when the remaining capacity equals the
reserve capacity, a delayed regeneration is
started.
9. Press the scroll
button again; the display will show
(only when the regeneration mode was set to 'Delayed' or
'Dlyd/Immd'):
Regen @
Press the up
or down
regeneration.
10. Press the scroll
button again; the display will show
(only when the regeneration mode was set to 'Dlyd' or
'Dlyd/Immd'):
Rsrv
Variable
Press the up
or down
capacity:
 Variable: the reserve capacity is calculated
automatically, based on the registered daily water
usage.
 Fxd: press the scroll
up
or down
capacity to a fixed amount.
11. Press the scroll
button again; the display will show:
AUX: Regen
Press the up
or down
of the auxilliary contact:
 Regen: aux. contact is powered during entire
regeneration (does not include refill and brine
preparation cycles!).
 Chlor.Cell: aux. contact is powered at start of
brine draw/slow rinse cycle. Press the scroll
button again and press the up
button to set the duration of activation of the
chlorination cell.
 Maintenance: aux. contact is powered when
maintenance reminder is triggered.
ELECTRONIC CONTROL PANEL
Eco
Cycle 1
Cycle 2
Cycle 3
button to set the
2:00
button to set the time of
button to set the reserve
button again and press the
button to set the reserve
button to set the function
or down
 Error: aux. contact is powered when timer failure
occurs.
12. Press the scroll
Exit
Press the up
into the NOVRAM® and exit the programming mode.
Page 9
button again; the display will show:
or down
button to save the settings

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for H2OPTIMO H2O-CS-ECO