DIAGNOSTICS MODE
In the Diagnostics mode several operating parameters
can be consulted; particularly during a service intervention,
these parameters can be helpful to identify the cause of a
problem or malfunction.
Before entering the Diagnostics mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode!
ACCESSING THE DIAGNOSTICS MODE
1. Press the scroll
button and hold it for 6 sec until the
display shows:
System Check
2. Within 10 sec, press the down
show:
Regen XXdays ago
You are now in the Diagnostics mode.
Press the scroll
diagnostics parameter.
AVAILABLE DIAGNOSTICS PARAMETERS
Regen X days ago: number of days since last
regeneration.
In Srvc: total number of days in service.
# of Regens: number of regenerations since installation.
TotVol: total volume of treated water since installation.
LastSet: number of days since last change of configuration
parameter or hardness of incoming untreated water.
InstFlow: instantaneous flow rate through appliance.
AvgVol: calculated average daily water usage.
LastRgn@: consumed capacity at last regeneration.
Capacity: calculated capacity between regenerations.
MaintCnt: current status of maintenance reminder
counter (counting up).
MP Resets: number of resets of microprocessor.
Memory Reset: number of corrupt memory start-ups.
CapToUse: remaining capacity.
Fill: length of refill cycle of last regeneration.
Reserve: calculated reserve capacity.
EZ3P5f EZ3PB r14: software version.
EXITING THE DIAGNOSTICS MODE
1. Press the scroll
button repeatedly until the display
shows:
Exit
Press the up
or down
Diagnostics mode.
ELECTRONIC CONTROL PANEL
button; the display will
button to advance to the next
button to exit the