PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
button and hold it for 2 sec until the
display shows:
Language:English
Press the up
or down
language.
2. Press the scroll
button again; the display will show:
Set time:
Press the up
or down
day.
3. Press the scroll
button again; the display will show:
HardUnit:
Press the up
or down
measure for water hardness. Make sure it is identical
to the unit of measure of the water hardness test kit
or water analysis report that is used to determine the
hardness of the incoming untreated water!
4. Press the scroll
button again; the display will show:
Set Hardn: XX °f
Press the up
or down
of the incoming untreated water.
5. Press the scroll
button again; the display will show:
Exit
Press the up
or down
into the NOVRAM® and exit the programming mode.
ELECTRONIC CONTROL PANEL
button to set the
8:01
button to set the time of
°f
button to set the unit of
button to set the hardness
button to save the settings
PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
All configuration parameters on this appliance have
been pre-programmed in the factory, to offer optimal
performance in a wide range of applications and situations.
See table at the end of this manual for default configuration
parameter settings.
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
display shows:
System Check
2. Within 10 sec, press the up
show:
Units:Metric
Press the up
measure (Metric or US).
3. Press the scroll
MaintInt: OFF
Press the up
maintenance reminder function by setting the
maintenance interval, or deactivate the maintenance
reminder function.
4. Press the scroll
ExCap:5.1°f M3/L
Press the up
exchange capacity per litre of resin.
5. Press the scroll
Resin:XXX liters
Press the up
of resin.
6. Press the scroll
Override: 7 days
Press the up
of days between regenerations.
7. Press the scroll
Cycle 1: XXX sec
Press the up
of the regeneration cycle.
Page 8
button and hold it for 6 sec until the
button; the display will
or down
button to set the units of
button again; the display will show:
or down
button to activate the
button again; the display will show:
or down
button to set the
button again; the display will show:
or down
button to set the volume
button again; the display will show:
or down
button to set the number
button again; the display will show:
or down
button to set the length