Loop Test; Error Codes Loop Test - Philips FW-D5/21 Service Manual

Dvd mini system
Table of Contents

Advertisement

3.5 LOOP TEST

At the start of the loop test, the display will show the result of
the interactive player test:
The left side of the display contains a 3-digit code, which can
have a value between 000 and 111. these values are to be
interpreted as follows:
Display
Indication for each module
Value
Basic Engine
000
ok
001
ok
010
ok
011
ok
100
faulty
101
faulty
110
faulty
111
faulty

ERROR CODES LOOP TEST

ERROR CODE
0601
0901
1101
1102
1103
1104
1201
1202
1203
1204
1301
1302
1303
1304
1601
5201
5202
5203
5204
5401
5402
5403
5404
Mono
Display
PCB
PCB
ok
ok
ok
faulty
faulty
ok
faulty
faulty
ok
ok
ok
faulty
faulty
ok
faulty
faulty
NUCLEUS NUMBER ERROR DESCRIPTION
6
Calculated checksum of FLASH is not correct
9
The DVD DRAM is faulty
11
I2C bus busy before start
NVRAM access time-out
No NVRAM Acknowledge
NVRAM reply time-out
12
I2C bus busy
I2C bus not working
Slave controller not responding
Slave response is not correct
13
Parity error from basic engine to serial
Parity error from serial to basic engine
No communication between serial and basic engine
Communication time-out error
16
The SDRAM is faulty
52
I2c bus busy
I2c bus not working
Colour setup controller not responding
Colour setup controller response not correct
54
I2c bus busy
I2c bus not working
Scart switch controller not responding
Scart switch controller response not correct
9-7
The loop test will perform the same nuclei as the dealer test,
but it will loop through the list of nuclei indefinitely.
The display of the DVD player will show not only the 3-digits
indicating the correctly/faulty modules and the last found
error code, but also a loop counter indicating how many
times the loop has been gone through.
Note: Only faults within the scope of the diagnostic
software are detected.
Example:
FAULTY
MODULE(S)
The 2-digit after the hyphen indicates the number of times
the loop test has been performed.
The following 4-digits show the last error that was found
while running the loop test. The first 2 digits of this code
indicate which nucleus resulted in a fault and the next 2 digits
refer to the faultcode within that nucleus.
For further explanation of the error code, see list of error
codes on below.
LOOP
COUNTER
NUCLEUS
ERROR
PCS 103 851