4- DELAY – a delay on the output channel selected (from 0 to 7 ms in intervals of
a delay on the output channel selected (from 0 to 7 ms in intervals of
a delay on the output channel selected (from 0 to 7 ms in intervals of
0.5 ms)
5- HPF&LPF – adjusts the parameters of the High
adjusts the parameters of the High-Pass Filters (HPF) and Low
Pass Filters (LPF).
Pass Filters (LPF).
The symbol
indicates the parameter that will be changed by rotating the
indicates the parameter that will be changed by rotating the
PARAMETER button. Press the same button to select another parameter. The
PARAMETER button. Press the same button to select another parameter. The
PARAMETER button. Press the same button to select another parameter. The
frequency intervals permitted for each one are as follows:
frequency intervals permitted for each one are as follows:
LPF 35 Hz to 22 kHz and HPF from 10Hz to 16kHz.
LPF 35 Hz to 22 kHz and HPF from 10Hz to 16kHz.
6- PEQ – Parametric Equalizers: Up to 5 PEQs are allowed per output channel.
Parametric Equalizers: Up to 5 PEQs are allowed per output channel.
Parametric Equalizers: Up to 5 PEQs are allowed per output channel.
These filters may be of the following types:
These filters may be of the following types:
HiShelf, LoShelf, and PEQ, as indicated on the DT2006S panel by "{", "}", and
HiShelf, LoShelf, and PEQ, as indicated on the DT2006S panel by "{", "}", and
HiShelf, LoShelf, and PEQ, as indicated on the DT2006S panel by "{", "}", and
.
The "=" symbol indicates that the filter is switched off.
The "=" symbol indicates
Move the cursor to the Q adjust and turn the PARAMETER dial to select the
Move the cursor to the Q adjust and turn the PARAMETER dial to select the
Move the cursor to the Q adjust and turn the PARAMETER dial to select the
Hishelf and Loshelf type filters.
Hishelf and Loshelf type filters.
The amounts permitted for each parameter are as follows:
The amounts permitted for each parameter are as follows:
The amounts permitted for each parameter are as follows:
Frequency: 20Hz ~ 20kHz
Frequency: 20Hz ~ 20kHz
Q: 0.5 to 10
Gain: 12dB to +12d
Gain: 12dB to +12dB
HiShelf: 1kHz to 20kHz
HiShelf: 1kHz to 20kHz
LoShelf: 20Hz to 1kHz
LoShelf: 20Hz to 1kHz
7- LIMITERS – have the following parameters:
have the following parameters:
LEVEL – dB threshold
dB threshold
HOLD – Time that the limiter continues active after the Threshold is up (ms)
Time that the limiter continues active after the Threshold is up (ms)
Time that the limiter continues active after the Threshold is up (ms)