Main Part Inspection Method - Samsung TH026EAV Service Manual

System air conditioner
Hide thumbs Also See for TH026EAV:
Table of Contents

Advertisement

12-4 Main Part Inspection Method

Part
Room Temperature Sensor
Room Fan Motor
Stepping Motor
12-22
24867A(1)_TH026EAV_1.indd
22
Breakdown Inspection Method
Measure resistance with a tester
Normal
At the normal temperature 37kΩ~ 8.3kΩ(-7˚C~+30˚C)
Abnormal
∞, 0Ω . . . Open or Short
Measure the resistance between terminals of the connector (CN72) with a tester.
Normal
At the normal temperature (10˚C ~ 30˚C)
Compare terminal
Yellow, Blue
Yellow, Red
Abnormal
∞, 0Ω . . . Open or Short
Measure the resistance between the red wire and each terminal wire with a tester.
Normal
About 300Ω at the normal temperature (20˚C ~ 30˚C)
Abnormal
∞, 0Ω . . . Open or Short
*Refer to Table 12-3-4.
Resistance
Remark
404.4Ω ± 10%
Main
Sub
340Ω ± 10%
Samsung Electronics
2006-04-03
ソタタ・9:49:26