Videx ART380N Installation And Programming Manual
Videx ART380N Installation And Programming Manual

Videx ART380N Installation And Programming Manual

Telephone interface

Advertisement

Quick Links

ART380N Rev03 TELEPHONE INTERFACE MANUAL
Installation and programming manual
Version 1.3
06/2013
1 of 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ART380N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Videx ART380N

  • Page 1 ART380N Rev03 TELEPHONE INTERFACE MANUAL Installation and programming manual Version 1.3 06/2013 1 of 19...
  • Page 2: Table Of Contents

    CONTENTS DESCRIPTION PAGE Introduction ------------------------------------------------- Mounting Instructions ------------------------------------------------- Safety notes ------------------------------------------------- Connections to the telephone line ------------------------------------------------- Dealing with other telephone equipment ------------------------------------------------- Dealing with Broadband ------------------------------------------------- Wiring directions ------------------------------------------------- Connecting more than one handset ------------------------------------------------- Lock release back EMF protection ------------------------------------------------- Cable size -------------------------------------------------...
  • Page 3: Introduction

    Introduction The Art380 is a self contained telephone interface module for use on an analogue telephone line. Its primary function is to enable a user to communicate with a telephone line and a door entry point (or points) from the same telephone handset. This handset can be a standard corded model, a cordless such as a DECT telephone or even a hands free telephone.
  • Page 4 When connecting additional equipment to a telephone line it is good practise to first check the equipment already installed by previous engineers. This includes any additional secondary sockets, digital set top box such as Sky Digital, faxes, modems, Broadband and REDCARE alarm monitoring etc.
  • Page 5: Wiring Directions

    A1 or A2. Maximum current output available is 100mA. +12V DC output Can only be used to power Videx serial bus modules designed to work with the Art380. 0V connection. Can only be used to power Videx serial bus modules designed to work with the Art380.
  • Page 6: Connecting More Than One Handset

    If more telephones are required. They should be connected to the Art380 via a REN booster (The REN booster is a third party product not supplied by Videx). IMPORTANT NOTE: When using a REN boost the Art.380 must be put into PABX mode. It will then be necessary to press ‘0’...
  • Page 7: Cable Size

    Cable size and type When running cables for any intercom system, these cables must be installed separately from the mains cables. All multi pair cables should be to CW1308 specification. (0.5mm twisted pair telephone cable). Max resistance = 10 Ohm. Lock release wires should be doubled up.
  • Page 8: Tones Overview

    understood and so is required to be entered again. If during the programming, a mistake is made, simple hang up the telephone and start again. Tones overview  Upon lifting the handset you should hear the telephone line tone. (If the system is in PABX mode you will still hear a line tone but this will be a higher frequency to the one normally heard on a telephone line.
  • Page 9 local use. Number of rings 21 X X = 0 to 9 (0 = 10 rings, 1 – 9 = number of rings) Door open time 22 X X = 0 to 9 (0 = 1 second, 1 – 9 multiplied by 2. i.e. X = 3, time = 6 seconds.
  • Page 10: Initial Setup

    Programming & User functions explained Initial setup: Begin by resetting the Art380 to the factory defaults: ** 371 33 1111 Note: If you are unable to reset using this process because you have enabled a code but are not sure what it is then follow the following manual reset procedure: 1.
  • Page 11: Dial In Facility Setup

    Setting up the auxiliary outputs There are two auxiliary outputs available on the Art380 labelled A1 and A2. These outputs are a switched negative (Open collector) and can be used for a number of facilities including activating dry contact relays. The outputs can be set to latch on activation or switch momentarily.
  • Page 12: Divert Call Setup

    Divert call setup The divert facility allow a call to be diverted to another telephone number. When in divert mode it is recommended you use a four digit access code to restrict the functions of the Art380 to authorised callers. Also see box above for divert time which is the time allowed before a call will clear.
  • Page 13: Specialised Setup

    Enable/Disable access code for Code Enabled or disabled local calls: 20 0 Enabled 20 1 Disabled (Default) Specialised setup The following options can be adjusted for specialised situations. For standard installations these setting will not normally need to be adjusted. Pulse mode: The pulse mode Code Pulse mode...
  • Page 14: Approval

    Speech adjustments Speech volume control is adjustable for both directions using the POTS on the entrance panel speaker unit. Additionally, speech volume towards the door panel can be adjusted from the telephone using the following procedure:- 1. Lift the handset and type ** 371 to enter programming mode 2.
  • Page 15: Troubleshooting Guide

    Option 2 : Check the line cord is connected to the incoming master socket and that the cord is not faulty. Option 3 : Check the new master socket fitted across terminals T1 & T2 of the Art380N has the wires connected to terminals 2 and 5.

Table of Contents