6.
It is highly recommended that a set of safety infra-red beams be used in conjunction with this product. The safety beams must be installed in such a way that
the product is prevented from running when anything is in the path of the door or gate.
7.
Over and above the recommendation to use safety infra-red beams with this product it is mandatory to install and use a safety beam set when using the
automatic closing feature. It is recommended that a warning light be fitted to any automation system.
1.
Is proficient in the use of the manual emergency release mechanism.
2.
Is issued with the documentation accompanying this product.
3.
Understands that the gate or door may not be operated out of clear sight.
4.
Ensures that children are kept clear of the gate or door area at all times, and that children do not play with the remote transmitters or any fixed trigger switches
linked to the system.
5.
Is instructed not to attempt to repair or adjust the automation system and to be aware of the danger of continuing to use the automation system in an unsafe
condition before a service provider attends to it.
6.
Is proficient in testing the unit's safety obstruction sensing system.
7.
Is aware of what to check for with regards to wear and tear that may need to be attended to from time to time by the service provider.
8.
Is aware that a fatigued battery may not be disposed of in the general refuse and must be handed in at a battery merchant for safe disposal. Before removing
the battery from the system the household mains must be disconnected. In the case of the motor unit being removed and scrapped, the battery must be
removed first.
Model
Primary power supply
Peak power consumption
Motor voltage
Maximum operations per day*
Traveller speed*
Operating temperature range
Anti-crushing safety sensing
Auxiliary supply output
Rated battery charging voltage 27.5Vdc
Built in receiver format
Receiver frequency
Memory
Applicable door types
Drawbar options(Ex-stock)
Applicable door sizes*
* Based on the assumption that the door is balanced correctly and moving freely.
ET DC BLUE ADVANCED USER 2013.012.24.11.2016
After Installation: It Is The Responsibility Of The Installer To Ensure The User:

TECHNICAL SPECIFICATIONS

DC BLUE ADVANCED Pico
220 – 240Vac @ 50hz
100W peak @ (220 -240vac)
24Vdc
50 full cycles per 24hrs @ a rate of Max. 5
per hour
8m/min
-10 to 50° C (14F to 122F)
Yes - Electronic digital profiling
24Vdc @ 250mA peak or 150mA continuous
ET BLU MIX © enhanced rolling code.
433.92Mhz
EEPROM
One piece trackless tip-up or multiple panel
sectional overhead single width doors
2.2m or 3.2m
<10m²
www.et.co.za
220 – 240Vac @ 50hz
120W peak @ (220 -240vac)
24Vdc
50 full cycles per 24hrs @ a rate of Max. 5 per
hour
8m/min
-10 to 50° C (14F to 122F)
Yes - Electronic digital profiling
24Vdc @ 250mA peak or 150mA continuous
27.5Vdc
ET BLU MIX © enhanced rolling code.
433.92Mhz
EEPROM
One piece trackless tip-up or multiple panel
sectional overhead double width doors
2.2m or 3.2m or 3.7m
<15m²
4
DC BLUE ADVANCED
0011014.005

Advertisement

loading

This manual is also suitable for:

Dc blue advanced