  • Page 1 SERVICE MANUAL MODEL: S-7330...
  • Page 2 TABLE OF CONTENTS WHAT TO DO WHEN ....................1-3 SERVICE ACCESS (1) FACE COVER, TOP COVER ........... 4 SERVICE ACCESS (2) BASE, BED COVER ..............5 SERVICE ACCESS (3) BELT COVER ................6 SERVICE ACCESS (4) FRONT COVER ............... 7 SERVICE ACCESS (5) REAR COVER .................
  • Page 11: Mechanical Adjustment

    MECHANICAL ADJUSTMENT PRESSER BAR HEIGHT AND ALIGNMENT When the presser foot is raised, the clearance between the presser foot and the needle plate should be 6.0 mm. When the presser foot is lowered, the edge of the foot and the feed dog window on the needle plate should be parallel.
  • Page 18 - 7.5 mm...
  • Page 25 first and the d value increases as you turn...
  • Page 27 finished , turn off the power switch.
  • Page 28 fingers and pull.
  • Page 30 r finger (with approximately 300 grams of pressure).Then, tighten the screws firmly.
  • Page 31: Replacing The Fuses

    REPLACING THE FUSES REPLACING THE FUSES TO REMOVE: 1. Remove the front cover (see page 7). 2. Remove the four setscrews and lift off the cover on printed circuit board "A". 3. Remove the fuse. (Pry it out with a screwdriver). TO INSTALL: 4.