Testing: Module Qw-5117; Measuring Current Consumption; Checking The Model - Casio ECW-M300E Service Manual

Module no. qw-5117
Table of Contents

Advertisement

77

TESTING: MODULE QW-5117

7-17

MEASURING CURRENT CONSUMPTION

This model starts correct positioning of the second hand in the Hand Set mode immediately after AC.
When it is functioning, the value of consumption current would be a little higher as the internal circuit
operation would be different from the usual status.
Measure the current value at 5 seconds after AC is performed.
* Measure within one minute while light is blocked from the watch face.
* Supply voltage is 2.5V.
7-77

CHECKING THE MODEL

Timekeeping mode
LCD �
LCD 2
Accuracy checking
mode
+
Except
for
, 
All lit
Except
for
Light alternates
Except
for
Solar cell-PCB ass'y contact checking mode
Bright
Any
Button
LCD �: SLR
LCD 2:Not displayed
SPEC
LCD �: 5064
LCD 2: 35�0
Current Home City;
default is TYO
LCD �: TYO
LCD 2:Not displayed
Dark
LCD �: SLR
LCD 2: 8888
– �� –
�� – –
QW-5117
Any Button
+
Aging mode
LCD �: AGE
(To NYC)
Switcing home city
mode
LCD �: NYC
LCD �: LON
LCD �: BER
LCD �: HKG
LCD �: TYO
,