Blower Data
EL296UH110XV60C BLOWER PERFORMANCE (less filter)
BOTTOM RETURN AIR
0 through 0.8 in. w.g. (Heating) and 0 through 1.0 in. w.g. (Cooling) External Static Pressure Range
Heating Speed
1
DIP Switch
Settings
+24%
+18%
+12%
+6%
Factory Default
–6%
–12%
–18%
Cooling Speed
1
DIP Switch
Low
Settings
+
1060
Factory Default
970
885
Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings.
1
Factory default setting.
2
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT.
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is selectable at 28%, 38%, 70% and 100% of the selected second stage cooling speed - minimum 450 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
First Stage Heating Speed - cfm
1385
1475
1355
1370
1200
1140
1070
980
First Stage Cooling Speed - cfm
Medium-Low
Medium-High
1245
1345
1145
1265
1025
1110
HEATING
Second Stage Heating Speed - cfm
COOLING
Second Stage Cooling Speed - cfm
High
Low
2
1545
1560
1395
1405
1250
1270
Page 54
1965
1880
1790
1725
1630
1550
1460
1345
Medium-Low
Medium-High
1740
1930
1565
1775
1425
1610
High
2
2125
1945
1770