Appendix B: Timing Diagrams; B1: Parallel Colour Channels Output Modes - XIIMUS 1024CTI User Manual

Table of Contents

Advertisement

10.2
APPENDIX B:
10.2.1 B1:
Parallel colour channels output modes
Version:
2.01
Date:
7 June 2006
Firmware L1: R18 for 20 MHz models
R17 for 25 MHz models
R16 for 33 MHz models
R15 for 40 MHz models
Firmware L2: D14
FVAL is constantly HIGH. DVAL is identical to LVAL.
TVI XIIMUS 512CTi, 1024CTi and 2048CTi
Parallel Output Modes
Symbol
T1
NewLine low (CC1)
Line Scan Period
T2
3 x 512 pixels
3 x 1024 pixels
3 x 2048 pixels
T3
Delay to Change of Line
1
T4
Effective Integration Time
T5
Delay to Exposure Control active (CC2 ... CC4)
1 Please note the jitter of one STROBE clock period.
There is no jitter, if the Line Scan Period equals an even number of pixel clocks.
© TVI Vision, 18 October 2006
XIIMUS R-GB-IR CL User Manual.
Timing diagrams
Parameter
20
MHz
25
MHz
33.3 MHz
40
MHz
20
MHz
25
MHz
33.3 MHz
40
MHz
20
MHz
25
MHz
33.3 MHz
40
MHz
20
MHz
25
MHz
33.3 MHz
40
MHz
Min.
Max.
Unit
80
-
ns
30.1
-
µs
24.2
-
18.3
-
15.4
-
55.7
-
44.7
-
33.7
-
28.2
-
106.9
-
85.6
-
64.4
-
53.8
-
0.39
0.44
µs
0.45
0.49
0.52
0.55
0.54
0.565
2
-
µs
2
-
µs
Version 1.2
page 31 ( 57 )

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

512cti2048cti