Phone Power During Calibration; Battery; Power Supply; Dummy Battery - Sony Ericsson Z555 Installation Instruction

Electrical
Table of Contents

Advertisement

3.7

Phone Power during Calibration

There are two options for powering the phone during calibration, a fully charged Battery
or a Power supply with a Dummy Battery, both are acceptable.
3.7.1

Battery

A fully charged Sony Ericsson battery approved for this phone model must be used. The
part number can be found in the Mechanical Equipment List.
3.7.2

Power Supply

A Power Supply according to Electrical Equipment List must be used.
Set the output of the Power Supply as follows
Voltage: 3.8Vdc
Current: 2.0Amps
3.7.3

Dummy Battery

A Dummy Battery is to be used together with a power supply to power the phone.
Connect the cables from the battery eliminator to the power supply, red cable to positive
output terminal and black cable to negative output terminal. There is a 3-position switch
on the Dummy Battery that should be set to position "B".
3.8

RF Connection

Connect the RF-cable between the RF-port of the Test set and the RF Probe. Assemble
the RF Probe to the RF-holder according to the information in the Test Instruction
Electrical.
1208-3975 1
©
Sony Ericsson Mobile Communications AB
Installation Instruction, Electrical
6(11)