14A
SETTINGS
PARAMETERS
Automatic reclosure time (0 = off)
AUTOMATIC
1
Seconds of delay before the gate recloses automatically
CLOSING TIME
after opening
Reclosing time after transit (0 = off) Seconds of delay
AUTOMATIC
before the gate recloses automatically after excitation of
2
CLOSING AFTER
photocell 1 during opening or with the gate open.
TRANSIT
Motor sensitivity, sensitivity when detecting an obstacle.
3
SENSITIVITY
1 = minimum sensitivity, maximum force on obstacle
10 = maximum sensitivity, minimum force on obstacle
Motor speed during opening
1 = minimum
2 = low
OPENING
4
SPEED
3 = medium
4 = high
5 = maximum
Motor speed during opening deceleration phase.
1 = minimum
2 = low
SLOW DOWN
5
OPENING SPEED
3 = medium
4 = high
5 = maximum
Motor speed during closing
1 = minimum
2 = low
6
CLOSING SPEED
3 = medium
4 = high
5 = maximum
Motor speed during closing deceleration phase.
1 = minimum
2 = low
SLOW DOWN
7
3 = medium
CLOSING SPEED
4 = high
5 = maximum
0 = Normal (OP-ST-CL-ST-OP-ST...)
1 = Alternate STOP (OP-ST-CL-OP-ST-CL...)
8
STEP BY STEP
2 = Alternate (OP-CL-OP-CL...)
3 = Apartment block – timer (always opens)
4 = Apartment block with immediate reclosure (always
opens. Closes if gate is open)
BASIC
DESCRIPTION
CAUTION: the parameters may vary with respect to those in the
table below, depending on the motor to be installed.
DEFAULT
0
0
3
4
1
4
1
0
23
MIN.
MAX.
UNIT
0
900
0
30
0
10
1
5
1
5
1
5
1
5
0
4
s
s