1. NUMBERING SYSTEM
4
Capacity of pilot
7. standard
8. high flow
2. TECHNICAL DATA
2.1. Performance
Maximum service temperature range: (refer to the marking on the apparatus).
Standard Instrument: - 40 °C to + 85 °C (-40°F to +185°F)
Storage temperature: - 55°C to + 90°C (-67°F to + 194°F)
The components of the I/P Module are protected by a metallic housing. Housing electrical protection index: IP 66.
2.2. Schematic
REP.
4
Spring end
4b
Zero nut
4c
Zero lock nut
5
Feedback spring
8
Socket head screw
* O'ring seal is not visible.
ATEX Instruction Manual GEA19513 – 03/2012
4700E and 4800E Series Electropneumatic Positioners
Signal span
0. 4–20 mA
1. 20.7 to 103.5 KPa (3 to 15 psi)
2. 41.4 to 206.8 KPa (6 to 30 psi)
Performance (% of the signal range)
Dead Zone
Hysteresis
Repeatability
Sensitivity
Conformity
Input impedance
Designation
Mounting
0. Rotary
1. Linear
4700E
< 0.5
< 0.5
0.5
0.3
± 1
170 ohms
REP.
Designation
12
Supply gauge
13
Output gauge
19
Vent plug
43
Plug
4 – 9
P - Pneumatic
E - Electropneumatic
4800E
< 0.5
< 0.8
0.5
0.5
± 1
170 ohms
(C)
REP.
Designation
C
Cover
J (*)
O'ring seal
O
Output
S
Supply
V
Safety screw
Type
(J*)