Page 1
Cochran EMC-14 Owner's Manual English - Metric Ver: EMC-14m -1.50 For your records, please fill in the following: Serial Number: _________________________ Your Name: ____________________________ Your Contact:___________________________ ______________________________________ ______________________________________ Purchase Date: _________________________ Purchase Place: ________________________ Address: ______________________________ ______________________________________ ______________________________________...
Page 3
The EMC-14 will not turn on if the altitude is greater than 4,875 meters or if the battery voltage is less than 1.6 volts, or a fault is detected during the self-test.
Page 4
DIVE MODE: Whether in the Surface Interval, PreDive Prediction Mode, Programming Mode or the Logbook Mode, the EMC-14 will automatically enter the Dive Mode whenever the unit determines that it is in water deeper than 1.5 meters.
Page 5
There is no compensation above 75 degrees F. Bottom Time will begin once the EMC-14 senses that the diver has descended below 1.5 meters (see Training Mode) and continues until the diver has ascended above one meter. The maximum Bottom Time displayed is 9 hours 59 minutes.
Page 6
1.5 meter and will exit the Dive Mode at .3 meters instead of 1 If the diver surfaces before satisfying his decompression obligation, the meter. Also the Post Dive Surface Interval may be extended, via the EMC-14 will continue to give out-gassing credit as if it were in a dive, but ® Analyst...
Page 7
Identification Description Figure Page Clock – if enabled PreDive Prediction NOTE: Once the EMC-14 is placed in Clock Mode the unit will remain Misc. Information in that mode until exited by the diver. Depth Alarm, Max value is 55 or 99 meters.
Page 8
The Logbook is accessed via the Touch Contact Programming (see page Air only 15). This enables the diver to view dive statistics; the EMC-14 has the Single Blend Nitrox, 21 to 50% ability to provide diving data for the most recent 256 dives. The most recent dive will be displayed first.
Page 9
For High CNS, see “OXYGEN TOXICITY FACTORS” on page 7. SENSOR WARNING: The EMC-14 has the capability of monitoring the integrity of it‟s' sensors, both the low-pressure (depth/altitude) and the temperature. When the computer detects an error in one of the transducers, the diver is alerted to this condition by the illumination of the “WARNING”...
Page 10
TOUCH CONTACT PROGRAMMING SCREENS: The following are all of the screens that the EMC-14 is capable of presenting in the Touch Programming Mode. Refer to the particular configuration for appropriate screens. CENTRAL NERVOUS SYSTEM (CNS) TOXICITY: By the accepted definition of CNS toxicity, should a PO value of greater than 1.6 ATA be...
Page 11
This option enables the Training Mode for the EMC-14. In this mode the option may also be set via the Touch Contact Programming. As shipped EMC-14 will enter the Dive Mode at .6 meters instead of 1.5 meters and from the factory, the Depth Alarm is set for 39 meters.
Page 12
O-rings are properly installed. Depth Accuracy +/- 1% of full scale (+/- 1.1 meters) Replace the bottom of the EMC-14 on the main unit ensuring that Maximum Altitude 1,875 meters, seamless the index tab on the base is fitted to the index slot of the lens.
Page 13
COCHRAN and its SCUBA use for 24 months from the original date of shipment from distributors and retailers will not be held liable for any personal injuries or COCHRAN.
Page 14
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE Should it be desired to initiate a dive PRIOR to completing the adaptation time, the EMC-14 will treat this dive as a repetitive dive in its algorithm, EXCLUSIVE AND IN LIEU OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESSED OR IMPLIED.
Page 15
TABLE OF CONTENTS FIGURES INDEX Page Number Fig # Page Number Product Introduction Self-Test Screen Side Touch Contacts Surface Interval - Primary Screen - No Nitrogen Turning the Product On & Off Surface Interval - Alternate Screen - No Nitrogen - Time 1 Main Operating Modes 3a Surface Interval - Alternate Screen - No Nitrogen - OTU 1 Surface Interval...
Need help?
Do you have a question about the EMC-14 and is the answer not in the manual?
Questions and answers