www.divecochran.com
Cochran
EMC-20H
Air Only
Owner's Manual
English - Imperial
Ver: CmdrEMC-20H Air-1.00
For your records, please fill in the following:
Serial Number: _________________________
Your Name: ____________________________
Your Contact: __________________________
______________________________________
______________________________________
Purchase Date: _________________________
Purchase Place: ________________________
Address: ______________________________
______________________________________
______________________________________

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMC-20H and is the answer not in the manual?

Questions and answers

Summary of Contents for Cochran EMC-20H

  • Page 1 Cochran EMC-20H Air Only Owner's Manual English - Imperial Ver: CmdrEMC-20H Air-1.00 For your records, please fill in the following: Serial Number: _________________________ Your Name: ____________________________ Your Contact: __________________________ ______________________________________ ______________________________________ Purchase Date: _________________________ Purchase Place: ________________________ Address: ______________________________...
  • Page 3: Product Introduction

    When there is no remaining Nitrogen residual, the Dive The EMC-20H will not turn on if the altitude is higher than 16,000 feet, the of Day is set to zero and the computer is referred to as a “clean” system.
  • Page 4: Dive Mode

    75 degrees F. depth. Bottom Time will begin once the EMC-20H senses that the diver has The Remaining No-decompression Time and “NDC” legend will be descended below five feet (see Training Mode) and continues until the replaced with Decompression Time and “DEC”...
  • Page 5: Post Dive Interval

    Clock Mode the Dive Computer will be in the “Sleep” mode. minutes if the unit is in the Training Mode) after a dive, the EMC-20H is in The Clock Mode can be selected with or without an Alarm. If the Alarm the Post Dive Interval.
  • Page 6: Clock Programming Screens

    TACLITE™ On Time. Allowed value 0 to 99 Logbook NOTE: Once the EMC-20H is placed in Clock Mode the unit will remain in that mode until exited by the diver. TOUCH PROGRAMMING MODE: NOTE: To enable the Programming Mode, the EMC-20H must be on the Surface and not in the Post Dive Interval.
  • Page 7: Information Display

    The Taclite™ dwell (on) time can be set so that when the face on the EMC-20H is tapped the Taclite™ will stay on from 1 to 98 seconds. If the dwell time is programmed to ‘0’ the Taclite™ will never come on, if programmed to 99 the Taclite™...
  • Page 8: Logbook Screens

    If an audible alarm is being issued, the computer will not switch to the Alternate display nor will the TACLITE™ activate. SENSOR WARNING: The EMC-20H has the capability of monitoring the integrity of its' sensors, both the low-pressure (depth/altitude) and the temperature.
  • Page 9: Inter-Dive Events

    This option enables the Training Mode for the EMC-20H. In this mode Ascent Rate Responsiveness (0 to 7): This option determines the the EMC-20H will enter the Dive Mode at 2 feet instead of 5 feet and exit responsiveness or sensitivity of the Ascent Rate Bar Graph. Zero is the Dive Mode at 1 foot instead of 3 feet.
  • Page 10: Product Specifications

    If the batteries are allowed to discharge too low, or if removed for too Decompression Ceiling 0 to 410 feet, 10-foot increments long, the EMC-20H may enter a state where it will not turn on even with Dive Summary Storage up to 1024 Dives new batteries.
  • Page 11: Analyst ® Personal Computer Interface

    INTERFERENCE STATEMENT cold, or other conditions which COCHRAN may deem to be outside the NOTE: This equipment has been tested and found to comply with the intended scope of this Limited Warranty are not covered. This Limited limits for a Class B digital device.
  • Page 12: Product Certifications

    Should it be desired to initiate a dive PRIOR to completing the adaptation No Cochran Undersea Technology dealer, agent, or employee is time, the EMC-20H will treat this dive as a repetitive dive in its algorithm, authorized to make any modification, extension, or addition to this taking into account the "residual"...
  • Page 13: Table Of Contents

    TABLE OF CONTENTS FIGURES INDEX Page Number Fig # Page Number Product Introduction Side Touch Contacts Self-Test Screen Turning the Product On & Off Surface Interval - Primary Screen - No Nitrogen Main Operating Modes Surface Interval - Primary Screen - With Nitrogen Surface Interval 10a Dive Mode Dive Mode...
  • Page 15 Cochran EMC-20H Air Only Owner's Manual English - Imperial Ver: EMC-20H Air-2.00 1758 Firman Drive Richardson, Texas 75081, USA Phone 972-644-6284 972-644-6286 www.divecochran.com...

This manual is also suitable for:

Commander emc-20h

Table of Contents