Failure
2.1 Power On /
Off
2.2 Software Flash
2.3 Charging
2.4 Charging indicator (RED LED)
2.5 Hands-Free connection (PHF)
2.6 SIM
2.7 Display
4/000 21-2/FEA 209 544/112 C
©
Company Internal
Sony Ericsson Mobile Communications AB
Failure Symptom
Current draw greater than 300 mAmps
Current draw when powered off
Hangs at gray display. Constant
vibration. Will not power off.
Draws current when pushing power key,
returns to zero
Powers on by itself after installing
battery. Will not power off.
No response when pushing power key
(no current change)
Other symptoms
USB icon does not flash
Error message "USB device not
recognized"
USB icon flashes
Progress indicator appears with red X
No response from computer or phone
Measure V2201 with positive lead on
the Anode.
VDC should equal 0.15 to 0.19.
Other symptoms
Charging from power outlet
Charging from computer via USB
Measure V2201 with positive lead on
the Anode.
VDC should equal 0.15 to 0.19.
Trouble Shooting Guide, Electrical
Repair Action
N2000
K790 ONLY –
N1100
K800 ONLY –
A1200 – Approved Centers Only
K790 ONLY –
N1100
K800 ONLY –
A1200 – Approved Centers Only
B2100
D2301
N2200
Replace S2500 if damaged
V2504
Replace S2500 if damaged
Replace X2200 if damaged
N2000, D2301
N2300, D2304
D2301
V2301
If VDC is outside of range, then
replace V2201
V2220
D2301, D2304
V2202
N2000
If VDC is outside of range, then
replace V2201
V2220
V3110
N4202
N2000
Replace X2302 if damaged
N2000
Replace X3102 if damaged