Sanyo VPC-S3 Service Manual page 16

Hide thumbs Also See for VPC-S3:
Table of Contents

Advertisement

6. LCD Panel Adjustment
[CP1 board (Side B)]
CL541
VR501
6-1. LCD VcomPP Adjustment
Preparation:
POWER switch: ON
Adjusting method:
1. Double-click on the DscCalDi.exe.
2. Adjust LCD "VCOMPP" so that the amplitude of the CL401
waveform is 5.60 V ± 0.05 Vp-p.
CL401 waveform
6-2. LCD VcomDC Adjustment
Adjusting method:
1. Adjust LCD "VCOMDC" so that the amplitude of the CL401
waveform is 4.10 V ± 0.05 Vp-p.
CL401 waveform
CL401
CL402(GND)
5.60 V
± 0.05 Vp-p
4.10 V
± 0.05 Vp-p
GND
(CL402)
3-7. Factory Code Setting
1. Check the "Factory Code" display within the Setting group.
2. For U.S.A., Canada and NTSC general area
If "FC_SANYO_U" does not appear, click on the "
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_U".
3. For Europe and PAL general area
If "FC_SANYO_EX" does not appear, click on the "
located on the right of the "Factory Code" display BOX and
select "FC_SANYO_EX".
3-8. Language Setting
1. Click on the "
" mark located on the right of the
"Language" display BOX.
2. Select language. (Default is English.)
3. End "DscCal" and remove the camera before turning the
camera power OFF.
Calibration
Upload
AWB
Firmware
Focus
Image
UV Matrix
Cal Mode
Initialize
OK
EVF
Cal Data
LCD Type
OK
USB storage
Get
VID
PID
Set
– 16 –
LCD
R Bright
B Bright
RGB Offset
Gain
Tint
Phase
VCO
H AFC
Test
Set
Serial
Set
Set
Rev.
Set
" mark
" mark
VCOMDC
VCOMPP
Hall Cal.
Setting
Language
Video Mode
Factory Code