6-13 HIDDEN SERVICE MENU
HIDDEN SERVICE
AIR-SENSOR
EXECUTE
LAMP ALARM
NONE
STARTUP TYPE
1
SOFT RESET
SOFT RESET
If this is executed, all of the user data is initialized.Never use it when not required.
6-15 RUN TIME window
Set operating time display method (accumulated lamp time display method)
1. Select " OPTION" from the Advanced menu, then place the cursor on the "LAMP TIME".
2. Press the [
], [ENTER] or [RESET] button.
3. Press the [Reset] button once, then press [KEYSTONE] button of the remote control for 3 seconds or
more to display the screen shown below. (The menu will close after 10 seconds if there are no further
operations.)
4. Use [ ] or [ ] to select the usage status number. (The usage status is as shown below.)
Usage status number
CP-X600(EDX40K3)
To display the OSD for "HIDDEN SERVICE MENU" set up.
By the control panel
1. Display the Advanced menu by
the "MENU" button.(If EASY
MENU appears, choose "Go to
Advanced menu" to display
ADVANCED MENU.)
2. Select the "OPTION" on the
menu.
3. Continue press the button [ ]
fi rst, then press the button [ ]
together with "INPUT", and hold
for 3 seconds.
RUN TIME
LAMP
1234 h
NORMAL
1000
h
WHISPER
234
h
AC
2000
h
On
1
Off
0
No.0
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
32
By the remote control transmitter
1. Display the menu by the
"MENU" button. (If EASY
MENU appears, choose "Go to
Advanced menu" to display
ADVANCED MENU.)
2. Select the "OPTION" on the menu.
3. Press the "MAGNIFY OFF"
button.
Next hold the "MAGNIFY OFF"
button for 3 seconds.
Lamp time
Lamp time(Normal)
Lamp time(Whisper)
AC energizing time
Number of times on
Number of times off
Usage status number(See below)

Advertisement