7 Illumination Problems

Problem Area
Items to Inspect
Keypad
Before proceeding !
Illumination:
Inspect both halves of the dome foil
The entire
assembly to circuit board connection
keypad will not
illuminate
If the issue has not been resolved !
If the issue has not been resolved !
Keypad
Perform the following action !
Illumination: A
portion of the
keypad does not
illuminate
If the issue has not been resolved !
4/000 21-1/FEA 209 544/123 A
©
Company Internal
Sony Ericsson Mobile Communications AB
Repair Action
Perform a setting reset
If dirty or oxidized – Clean both
halves of the connection
If the portion of the connection on
the dome foil assembly is damaged -
Replace the dome foil assembly
If the portion of the connection on
the circuit board is damaged – Send
to a repair location allowed to
perform electrical repairs on this
product
Replace the dome foil assembly, if it
has not been replaced
Send to a repair location allowed to
perform electrical repairs on this
product
Replace the dome foil assembly
Send to a repair location allowed to
perform electrical repairs on this
product
Trouble Shooting Guide, Mechanical
Inspection Reference
18(30)