Samsung RF28HDEDBSR Service Manual page 83

French door refrigerator
Hide thumbs Also See for RF28HDEDBSR:
Table of Contents

Advertisement

TROUBLESHOOTING
11) PANTRY Room Damper Heater has trouble(OPTION)
ERROR Code
Measure the voltage of Resistance
between ① - ② after
CN77 connector open / 1350 ohm ± 7%
Initial
power On Heater off
MICOM
#56
3.5V ~
condition
4.8V
☞ Checking method of Flex Zone Room Damper
resistance CN77-"1"(Black) ↔ "2"(Brown)
** Ω∞: Open (wire disconnection,
disconnection) trouble / 0Ω: Short trouble
Working
heater
3.5V ~
0V
4.8V
heater
Start
Start
NO
Is Damper Heater
normal?(about135ohm)
YES
YES
NO
Is MAIN PCB connector
(CN77) inserted correctly?
YES
YES
NO
Is the input voltage of
IC01 MICOM #56 normal?
YES
YES
Normal(recheck)
83
Bad contact of connector/ insert correctly
1) Wire connector
2) Replace Heater
1) Recheck the wire
2) Replace PCB MAIN